Wisotronic dialog 1-Channel Central Control Unit EWFS - Warema
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> <strong>Central</strong><br />
<strong>Control</strong> <strong>Unit</strong> <strong>EWFS</strong> ® This operating mode influences the way the sun control works. Continue here if<br />
6.3.7 Temperature control in the<br />
"Enable sun" operating<br />
mode<br />
you have selected this operating mode. Otherwise skip this section. The following<br />
values can be changed:<br />
Operating mode:<br />
Enable sun<br />
Temp.<br />
limit<br />
OFF<br />
—24...<br />
+74°C<br />
Temp.<br />
limit<br />
ON<br />
—24...<br />
+74°C<br />
Fig. 6-11:<br />
Temperature control: Values which can be changed in the "Enable sun" operating<br />
mode<br />
6.3.7.1 Temperature control<br />
limit "ON"<br />
The limit "ON" specifies the temperature from at the sun control is to be enabled<br />
again. Example: The sun control may become active again after the sun has<br />
heated up your conservatory and your ideal temperature has been reached. You<br />
can therefore specify for the <strong>Wisotronic</strong> at which temperature the sun control is<br />
to be enabled again in order to shade the conservatory. The setting range is from<br />
–24° to 74°C. If you do not want to evaluate the limit "ON", you can also set the<br />
value "0" (---) here. Proceed as follows in order to change the setting value:<br />
■<br />
Change to the temperature control menu as described above. Turn the<br />
function dial until the following display appears:<br />
Temperature<br />
limit ON<br />
26° C<br />
— + | }<br />
■ Change the setting values by using the buttons — + and then press the<br />
button | (save). If you want to exit the menu without saving the changes,<br />
press the } button twice consecutively. This completes the process.<br />