Wisotronic dialog 1-Channel Central Control Unit EWFS - Warema
Wisotronic dialog 1-Channel Central Control Unit EWFS - Warema
Wisotronic dialog 1-Channel Central Control Unit EWFS - Warema
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Wisotronic</strong> <strong>dialog</strong> 1-<strong>Channel</strong> <strong>Central</strong><br />
<strong>Control</strong> <strong>Unit</strong> <strong>EWFS</strong> ® The temperature control allows the comfortable control of your sunblind<br />
6.3.1 Basic functions<br />
depending on the internal and external temperature.<br />
1. The temperature control can be activated or de-activated completely.<br />
2. The <strong>Wisotronic</strong> controls your system by constantly comparing the temperature<br />
limits set by you with the local prevailing temperatures. If the temperature<br />
exceeds or drops below the limit, move commands are then triggered.<br />
Prerequisite: The required sensors have to be connected and assigned<br />
correctly.<br />
3. Two operating modes are available for the temperature control:<br />
The "Direct control" operating mode simply triggers move commands when<br />
the temperature exceeds or drops below the limit.<br />
The "Enable sun" operating mode can be used to activate/de-activate the sun<br />
control.<br />
4. Limits have to be specified in order for <strong>Wisotronic</strong> to fulfill all these control<br />
tasks. The temperature control can then be adapted optimally to your<br />
requirements.<br />
The following graphic provides an overview of the temperature control menu.<br />
The following values can be changed:<br />
Temperature<br />
control<br />
Temperature control ON/OFF<br />
Allocation temp. sensor<br />
Temperature<br />
mode<br />
Direct<br />
control<br />
Enable<br />
sun<br />
Temp.<br />
Limit<br />
UP<br />
—24...<br />
+74°C<br />
Temp.<br />
Limit<br />
OFF<br />
—24...<br />
+74°C<br />
Temp.<br />
Limit<br />
DOWN<br />
—24...<br />
+74°C<br />
Temp.<br />
Limit<br />
ON<br />
—24...<br />
+74°C<br />
Fig. 6-9:<br />
Temperature control: Values which can be changed.<br />
932806A0•816757•7974k0•08.10.2004 We reserve the right to carry out improvements 37