6.1.7 Sun control limit "OPEN" This function only makes sense if you have selected a slat product (external<br />
venetian blind or internal venetian blind) as the product type. This specifies the<br />
brightness from which the slats of external or internal venetian blinds are to be<br />
turned to a horizontal position, for example in order to let more light into the room<br />
when the sky is covered but bright. The setting range is from 0 - 99 klx. If you do<br />
not want to evaluate the limit "OPEN", you can also set the value "0"<br />
(---) here. Proceed as follows in order to change the setting value:<br />
■<br />
Change to the sun control menu as described above. Turn the function dial<br />
until the following display appears:<br />
Sun<br />
limit OPEN<br />
28 klx<br />
— + | }<br />
■ Change the setting values by using the buttons — + and then press the<br />
button | (save). If you want to exit the menu without saving the changes,<br />
press the } button twice consecutively. This completes the process.<br />
6.1.8 Sun control delay "OPEN"<br />
This function only makes sense if you have selected a slat product (external<br />
venetian blind or internal venetian blind) as the product type. A delay period can<br />
be assigned to the "OPEN" limit so that the slats are not turned open immediately<br />
whenever the intensity of brightness changes (for example if the clouds only<br />
become denser temporarily). This smooths the movement behavior of the sun<br />
protection and thus increases the comfort. The turn command is triggered and the<br />
slats are turned open if the limits are reached or if the value drops below these<br />
limits for the duration of the delay period. The setting range is from 0 - 99<br />
minutes. Proceed as follows in order to change the setting value:<br />
■ Change to the sun control menu as described above. Turn the function dial<br />
until the following display appears:<br />
Sun<br />
delay OPEN<br />
0 minutes<br />
— + | }<br />
■ Change the setting values by using the buttons — + and then press the<br />
button | (save). If you want to exit the menu without saving the changes,<br />
press the } button twice consecutively. This completes the process.<br />
6.1.8.1 The "OPEN" limit<br />
The following instructions for the setting of the "DOWN", "OPEN" and "UP" limits<br />
have to be observed in order for the sun control to function properly in connection<br />
with the "OPEN" limit:<br />
■<br />
■<br />
■<br />
The lowest value must always be the value for "UP", for example 5 klx<br />
The highest value must always be the value for "DOWN", for example 30 klx<br />
The value for "OPEN" must be set between these values, for example 10 klx.<br />
TIP<br />
In order to find the optimal setting for your sun protection<br />
system you should test various values on a bright day with<br />
varying cloud situations. This is the only way of obtaining the<br />
optimum result.<br />