Residential<br />
Gas<br />
ProMax ®<br />
SL<br />
For recirculating hot water loop systems<br />
A. O. <strong>Smith</strong> ProMax SL “side loop” gas water heaters are designed with side-mounted recirculating<br />
taps for installations with combination space heating/water heating applications (such as with air<br />
handlers) or any system requiring a recirculating hot water loop.<br />
All ProMax SL water<br />
heaters are equipped<br />
with side-mounted<br />
recirculating taps, like<br />
the standard-vent<br />
model shown above.<br />
ProMax SL water heaters are available in Standard Vent (including self-cleaning DynaClean II<br />
models), Direct-Vent, Power-Vent and Power Direct-Vent models. All models include the following<br />
features:<br />
• Commercial-grade PermaGlas lining for longer life<br />
• Durable, tamper-resistant brass drain valve<br />
• High-temperature DynaClean II diffuser dip tube reduces lime and sediment buildup<br />
• Eco-friendly Green Choice gas burner reduces NOx emissions by 33% compared<br />
to standard burners<br />
• Factory-supplied temperature & pressure (T&P) relief valve<br />
• Optional circulating loop connection assemblies available<br />
• 6-year warranty on tank and parts<br />
Standard Vent<br />
• Standard or self-cleaning models (equipped with advanced DynaClean II<br />
automatic sediment cleaning system)<br />
• C3 Technology system on 40- and 50-gallon models<br />
• Dual anode rods for superior protection against corrosion<br />
• Piezo igniter on C3 Technology models for easy “no-match” pilot ignition<br />
MODEL FIRST HOUR ENERGY GALLON BTU INPUT BTU OUTPUT RECOVERY DIMENSIONS<br />
NUMBER RATING FACTOR CAPACITY PER HOUR PER HOUR 90°F RISE DRAFT HOOD<br />
GALLONS NATURAL NATURAL GALLONS HEIGHT* DIAMETER OUTLET<br />
GCVH-40L 71 .59 40 40,000 29,600 40 59-7/8 18-1/2 3 or 4<br />
GCVT-40L 88 .60 38 50,000 35,000 48 58-1/2 20-1/2 4<br />
GCVT-50L 90 .58 48 50,000 38,000 51 60-7/8 20 4<br />
GCVX-50L 93 .58 50 65,000 50,100 67 63-7/8 22 4<br />
GCG-65L** 112 .55 65 65,000 49,400 67 63-1/4 22 4<br />
FCG-75L** N/A N/A 74 75,100 60,100 81 61 26-1/2 4<br />
XGV-40L 81 .63 40 40,000 30,400 41 63-1/2 20-1/2 3 or 4<br />
XGV-50L 97 .63 50 40,000 32,400 44 65 22 3 or 4<br />
GCVH-40Q 71 .59 40 40,000 29,600 40 59-7/8 18-1/2 3 or 4<br />
GCVT-40Q 88 .60 38 50,000 35,000 48 58-1/2 20-1/2 4<br />
GCVT-50Q 90 .58 48 50,000 38,000 51 60-7/8 20 4<br />
GCVX-50Q 93 .58 50 65,000 50,100 67 63-7/8 22 4<br />
GCG-65Q** 112 .55 65 65,000 49,400 67 63-1/4 22 4<br />
FCG-75Q** N/A N/A 74 75,100 60,100 81 61 26-1/2 4<br />
*Height to top of draft hood.<br />
**Not equipped with C3 Technology.<br />
12<br />
For propane gas inputs, further detailed information on warranties and technical specifications,<br />
visit www.hotwater.com to view and download specifications.