Pinouts and Function Description<br />
Appendix<br />
Below are the pinouts and function descriptions for the HS34’s male and female connectors. At a<br />
minimum, you must make the connections shown in the Universal Connections diagram. All<br />
other wiring connections depend on the external equipment you are connecting to the HS34.<br />
Many common radio and GPS connections are depicted in the Common Device Connections<br />
section below. Note that the pin numbers are labeled on the face of both the female and male<br />
connector.<br />
Male (on HS34) DB25<br />
Female (on HS34) DB25<br />
Pin# Function Pin# Function<br />
1<br />
Serial 1 RX (PC updates & second<br />
CDI + when deflected right<br />
1<br />
serial port)<br />
2 Serial 2 RX (SL30, GPS, etc) 2 VOR + when TO flag shown<br />
3 DSAB A 3 LOC +<br />
4<br />
M aster Power (10-30V, 250 mA<br />
GS + when up UP<br />
4<br />
maximum at 12V)<br />
5<br />
GP Output 1 (not currently<br />
GS + when FLAG shown<br />
5<br />
supported)<br />
6<br />
GP Output 2 (not currently<br />
DME Analog IN (0-8V,<br />
6<br />
supported)<br />
40mv/NM)<br />
7 G P 1 in (same as EMS GP in) 7 Resolver G<br />
8 GP 2 in ( same as EMS GP in) 8 Resolver D<br />
9 +5V out 9 Resolver F<br />
10<br />
GP 6 in (+15V GP in, not currently<br />
ARINC 429 RX 2 B<br />
10<br />
supported)<br />
11<br />
GP 5 in (+15V GP in, not currently<br />
ARINC 429 RX 1 B<br />
11<br />
supported)<br />
12<br />
GP 4 in (+15V GP in, not currently<br />
ARINC 429 TX B<br />
12<br />
supported )<br />
13 GP 3 in (same as EMS GP in) 13 ARINC 429 TX B<br />
14 Serial 1 TX 14 CDI + when Left<br />
15 Serial 2 TX 15 VOR + when From flag shown<br />
16 DSAB B 16 LOC -<br />
17 Master Ground 17 GS + when Down<br />
18 Contact in 4 ( same as EMS<br />
contacts) 18 GS + when Flag hidden<br />
19 Contact in 3 (same as EMS contacts) 19 Resolver C<br />
20 Contact in 2 (same as EMS contacts) 20 Resolver H<br />
21 Contact in 1 (same as EMS contacts) 21 Resolver E<br />
22 Marker Outer Input 22 ARINC 429 RX 2 A<br />
23 Marker Middle Input 23 ARINC 429 RX 1 A<br />
24 Marker Inner Input 24 ARINC 429 TX A<br />
25 Voice audio output (8V peak-peak) 25 ARINC 429 TX A<br />
<strong>EFIS</strong>-<strong>D100</strong> <strong>Installation</strong> <strong>Guide</strong> 7-11