04.01.2015 Views

EFIS-D100 Installation Guide - Dynon Avionics

EFIS-D100 Installation Guide - Dynon Avionics

EFIS-D100 Installation Guide - Dynon Avionics

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Appendix<br />

Wiring Instructions.<br />

Once you have physically mounted the OAT probe, route its<br />

attached cable to the EDC-D10A remote magnetic compass<br />

module. Your OAT comes with pins crimped on the 3 wires.<br />

Insert these 3 wires’ pins to the following pin numbers on the D9<br />

which plugs into the EDC-D10A. The front of the female<br />

connector is pictured at right. You will be inserting the pins into<br />

the back of this connector.<br />

<br />

<br />

<br />

Pin 2: Yellow wire<br />

Pin 7: Red wire<br />

Pin 8: Blue wire<br />

The exposed shield wires are not strictly required, but may help OAT performance in noisy<br />

environments. If you wish to connect the shield to ground, you may splice it into the blue wire or<br />

connect it to the EDC-D10A chassis.<br />

You may lengthen or shorten the connections between the OAT and EDC-D10A. Use the<br />

provided crimp connectors on the new wire leads.<br />

Do not make connections while the <strong>EFIS</strong>-<strong>D100</strong> is powered!<br />

OAT/TAS/DA DISPLAY<br />

You must set up the <strong>EFIS</strong>-<strong>D100</strong> to<br />

recognize the OAT. The <strong>EFIS</strong>-<strong>D100</strong><br />

supports two different types of OATs as<br />

well as a manual input of the outside<br />

temperature. To set this up, enter the<br />

menu system by pressing any button<br />

beneath an <strong>EFIS</strong> page, and press MORE<br />

> SETUP > MORE > OAT. Push the<br />

INSTALLED button (either button 1 or<br />

Installed<br />

Sensor<br />

Type<br />

No OAT installed, dial in OAT value<br />

N<br />

in OATSET menu<br />

1 <strong>Dynon</strong> P/N 100240-000<br />

<strong>Dynon</strong> P/N 100433-001– marked<br />

2<br />

with a black band near the sensor<br />

2) to toggle between N, 1 and 2. All OATs sold by <strong>Dynon</strong> since 2005 are P/N 100433-001, so<br />

you most likely need to select sensor type 2.<br />

Note: Set the OAT INSTALLED parameter to N when you either: a) do not have an OAT at all<br />

or b) have an OAT connected to EMS D37 connector. If you do not have an OAT in the system<br />

at all, the OAT info item will be surrounded by a box denoting that its value can be adjusted<br />

manually.<br />

To display the data from the OAT probe, press any button below an <strong>EFIS</strong> page to bring up the<br />

<strong>EFIS</strong> menu and press MORE > INFO. Select the side of the screen that you wish to display<br />

TAS/DA information on (LEFT or RIGHT). Push the button labeled OAT. The values for<br />

outside air temperature, density altitude and true airspeed will be shown.<br />

7-8 <strong>EFIS</strong>-<strong>D100</strong> <strong>Installation</strong> <strong>Guide</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!