Appendix<br />
Wiring Instructions.<br />
Once you have physically mounted the OAT probe, route its<br />
attached cable to the EDC-D10A remote magnetic compass<br />
module. Your OAT comes with pins crimped on the 3 wires.<br />
Insert these 3 wires’ pins to the following pin numbers on the D9<br />
which plugs into the EDC-D10A. The front of the female<br />
connector is pictured at right. You will be inserting the pins into<br />
the back of this connector.<br />
<br />
<br />
<br />
Pin 2: Yellow wire<br />
Pin 7: Red wire<br />
Pin 8: Blue wire<br />
The exposed shield wires are not strictly required, but may help OAT performance in noisy<br />
environments. If you wish to connect the shield to ground, you may splice it into the blue wire or<br />
connect it to the EDC-D10A chassis.<br />
You may lengthen or shorten the connections between the OAT and EDC-D10A. Use the<br />
provided crimp connectors on the new wire leads.<br />
Do not make connections while the <strong>EFIS</strong>-<strong>D100</strong> is powered!<br />
OAT/TAS/DA DISPLAY<br />
You must set up the <strong>EFIS</strong>-<strong>D100</strong> to<br />
recognize the OAT. The <strong>EFIS</strong>-<strong>D100</strong><br />
supports two different types of OATs as<br />
well as a manual input of the outside<br />
temperature. To set this up, enter the<br />
menu system by pressing any button<br />
beneath an <strong>EFIS</strong> page, and press MORE<br />
> SETUP > MORE > OAT. Push the<br />
INSTALLED button (either button 1 or<br />
Installed<br />
Sensor<br />
Type<br />
No OAT installed, dial in OAT value<br />
N<br />
in OATSET menu<br />
1 <strong>Dynon</strong> P/N 100240-000<br />
<strong>Dynon</strong> P/N 100433-001– marked<br />
2<br />
with a black band near the sensor<br />
2) to toggle between N, 1 and 2. All OATs sold by <strong>Dynon</strong> since 2005 are P/N 100433-001, so<br />
you most likely need to select sensor type 2.<br />
Note: Set the OAT INSTALLED parameter to N when you either: a) do not have an OAT at all<br />
or b) have an OAT connected to EMS D37 connector. If you do not have an OAT in the system<br />
at all, the OAT info item will be surrounded by a box denoting that its value can be adjusted<br />
manually.<br />
To display the data from the OAT probe, press any button below an <strong>EFIS</strong> page to bring up the<br />
<strong>EFIS</strong> menu and press MORE > INFO. Select the side of the screen that you wish to display<br />
TAS/DA information on (LEFT or RIGHT). Push the button labeled OAT. The values for<br />
outside air temperature, density altitude and true airspeed will be shown.<br />
7-8 <strong>EFIS</strong>-<strong>D100</strong> <strong>Installation</strong> <strong>Guide</strong>