DSAB Configuration<br />

Initial Setup<br />

As mentioned at the beginning of this chapter, configure your DSAB network only after all other<br />

installation steps have been performed, including updating all products to the latest version of<br />

firmware available from the <strong>Dynon</strong> <strong>Avionics</strong> web site at downloads.dynonavionics.com. To<br />

begin configuration, enter the <strong>EFIS</strong> > SETUP > DSAB menu. A full-page menu appears with<br />

three options: STATUS, CONFIGURATION, and BRIGHTNESS. Push DOWN▼ to select<br />

CONFIGURATION and then SEL► to enter the CONFIGURATION submenu. Note that if you<br />

press CONFIGURATION from an EMS-only product (via EMS > SETUP > DSAB), the display<br />

prompts you to begin the configuration process from an <strong>EFIS</strong>-based product.<br />

If this is not your first time configuring your DSAB network, a prompt appears asking if you<br />

wish to re-configure the network. If you do not want to re-configure, press NO; otherwise, press<br />

YES to proceed with configuration as if this is a first-time install.<br />

The first screen in the configuration process asks you to power on all devices in the system<br />

before pressing CONFIGURE NOW (button 1 or 2). After doing this, a second screen appears<br />

asking you to wait while the instrument detects all other devices connected via DSAB. While<br />

doing this, it assigns both the Bus Master and <strong>EFIS</strong> roles to itself.<br />

During network detection, the Bus Master attempts to automatically assign as many roles as it<br />

can. The following table describes the logic used in assigning roles for network devices.<br />

How role is assigned<br />

Bus Master Auto-assigned to instrument user is configuring on.<br />

<strong>EFIS</strong> Auto-assigned to instrument user is configuring on.<br />

If one EMS detected, assigned automatically.<br />

EMS If Bus Master is EMS (i.e., FlightDEK-D180) assigned automatically.<br />

If more than one non-bus-master EMS detected, user must assign.<br />

If one OAT detected, assigned automatically.<br />

If more than one OAT detected, user must assign.<br />

OAT<br />

Note that for an OAT to be used it must be connected to an instrument<br />

assigned the <strong>EFIS</strong> or EMS role (i.e., if configuring DSAB on a<br />

FlightDEK-D180 with no OAT attached, the OAT role cannot be assigned<br />

to another instrument in the system as the FlightDEK-D180 is already<br />

assigned both the <strong>EFIS</strong> and EMS roles).<br />

Compass Auto-assigned to instrument providing the <strong>EFIS</strong>/Bus Master roles.<br />

AP CTRL<br />

PANEL<br />

HS34<br />

<br />

<br />

<br />

<br />

If one AP74 detected, assigned automatically.<br />

If more than one AP74 detected, error displayed: Not a supported<br />

configuration.<br />

If one HS34 detected, assigned automatically.<br />

If more than one HS34 detected, error displayed: Not a supported<br />

configuration.<br />