EFIS-D100 Installation Guide - Dynon Avionics
EFIS-D100 Installation Guide - Dynon Avionics
EFIS-D100 Installation Guide - Dynon Avionics
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Instrument <strong>Installation</strong><br />
The metal shield around the EDC communication cable is connected to the short black/white<br />
wire emanating from the DB25. Connect this wire to ground.<br />
Power Inputs<br />
The <strong>EFIS</strong>-<strong>D100</strong> has three separate power inputs, located on the DB25 <strong>EFIS</strong> connector. Of the<br />
three, only Master Power is required to operate the instrument. The other two inputs provide<br />
redundancy. Below is a table that explains the three inputs and their purposes. All three of these<br />
inputs share a common ground signal, wired to pin 3 on the <strong>EFIS</strong> connector.<br />
<strong>EFIS</strong> Function<br />
DB25<br />
pin#<br />
1 Master<br />
Power<br />
2 Keep Alive<br />
Power<br />
3 Master<br />
Ground<br />
15 External<br />
Backup<br />
Power<br />
<strong>EFIS</strong> DB25 wire<br />
color<br />
Red<br />
Yellow<br />
Black<br />
(Not wired in<br />
<strong>Dynon</strong> harness)<br />
Description<br />
Provides primary power to the instrument.<br />
The <strong>EFIS</strong>-<strong>D100</strong> will switch on upon<br />
application of power. Connect to a switched<br />
power source. Will not be adversely affected<br />
by engine cranking.<br />
A very low current power input which is only<br />
used if both Master and External Backup<br />
Power are not applied. Keep Alive draws just<br />
enough current to keep the clock running. It<br />
draws less than 1 milliamp of current when<br />
not charging the internal backup battery.<br />
<strong>Dynon</strong> <strong>Avionics</strong> recommends not connecting<br />
the Keep Alive wire when the <strong>EFIS</strong>-<strong>D100</strong> has<br />
an internal battery installed or is connected to<br />
a GPS. Keep Alive is only used in<br />
installations with no battery or GPS to keep<br />
the clock running when the unit is powered<br />
off.<br />
Connect to ground. Must carry as much as 3<br />
amps.<br />
Will operate the <strong>EFIS</strong>-<strong>D100</strong> only if Master<br />
Power is not present. The transition from<br />
Master Power to External Backup Power will<br />
bring up a warning, requiring you to press<br />
ACK within 30 seconds to keep the unit<br />
operating. This warning will also display<br />
when transitioning from either Master or<br />
External Backup to Internal Battery power.<br />
<strong>EFIS</strong>-<strong>D100</strong> <strong>Installation</strong> <strong>Guide</strong> 3-3