Appendix<br />
output, connect this to the power inputs on the Encoder Converter. If your transponder does not<br />
include this switched power output, the Encoder Converter power connections should be made<br />
directly to your switched avionics power. Ensure that all avionics power is off before performing<br />
the wiring step of this installation.<br />
If your Altitude Transponder has either a strobe signal or a D4 pin, leave these pins unconnected.<br />
Transponder Pin<br />
A1<br />
A2<br />
A4<br />
B1<br />
B2<br />
B4<br />
C1<br />
C2<br />
C4<br />
Power (10V-30V)<br />
Gnd<br />
Strobe Signal<br />
Encoder Converter<br />
Wire Color<br />
Yellow<br />
Green<br />
White with Blue<br />
Blue<br />
Orange<br />
White with Red<br />
White with Green<br />
White<br />
White with Black<br />
Red<br />
Black<br />
No Connection<br />
The Gray code output of the Encoder Converter reports altitude not adjusted for barometric<br />
pressure, as required by FAA specification. The altitude reported by the <strong>EFIS</strong>-<strong>D100</strong> encoder will<br />
always match the altitude shown on screen when the BARO value is set to 29.92 inHg.<br />
STEP 2: CONNECTING TO THE <strong>EFIS</strong>-<strong>D100</strong><br />
Before wiring connections to the <strong>EFIS</strong>-<strong>D100</strong> check to ensure that the wire length between your<br />
Encoder Converter and your <strong>EFIS</strong>-<strong>D100</strong> is appropriate. Add or remove wire length if needed or<br />
desired. Customizing the wire length will facilitate an installation that is both cleaner and more<br />
secure.<br />
The only pins of interest on the <strong>EFIS</strong>-<strong>D100</strong> connector for the Encoder Converter installation are<br />
pins 13 and 21. The two wires exiting the Encoder Converter are the <strong>EFIS</strong>-TX and the <strong>EFIS</strong>-<br />
Ground, which are green (or red) and black respectively, and 2 feet in length. Connect these<br />
wires to the <strong>EFIS</strong>-<strong>D100</strong> 25-pin female harness.<br />
Ensure that your <strong>EFIS</strong>-<strong>D100</strong> is powered off. Then connect the black <strong>EFIS</strong> Ground wire to pin 21.<br />
Then, connect the green wire to pin 13 (Serial Encoder Transmit) on the <strong>EFIS</strong> harness.<br />
<strong>EFIS</strong>-<strong>D100</strong> <strong>Installation</strong> <strong>Guide</strong> 7-33