Maintenance<br />

Resetting the Lamp Counter<br />

Be sure to reset the Lamp counter after the lamp is replaced. When the Lamp counter is reset, the LAMP RE-<br />

PLACE indicator stops lighting and the Lamp replacement icon disappears.<br />

1<br />

2<br />

3<br />

Press the MENU button to display the On-Screen Menu.<br />

Use the Point 7 8 buttons to move the red framed<br />

pointer to the Setting Menu icon.<br />

Use the Point ed buttons to move the red framed pointer<br />

to Lamp counter and then press the SELECT button.<br />

A dialog box appears showing the total accumulated time<br />

of the lamp usage and the reset option. Select Reset and<br />

the “Lamp replacement counter Reset” appears. Select<br />

[Yes] to continue.<br />

Another confirmation dialog box appears, select [Yes] to<br />

reset the Lamp counter.<br />

Lamp counter<br />

Select Reset and the “Lamp<br />

replacement counter Reset<br />

” appears.<br />

✔Note:<br />

• Do not reset the Lamp counter without implementing lamp<br />

replacement. Be sure to reset the Lamp counter only after<br />

replacing the lamp.<br />

How to check Lamp Used Time<br />

Select [Yes],<br />

then another<br />

confirmation<br />

box appears.<br />

Select [Yes] again to reset the<br />

Lamp counter.<br />

The LAMP REPLACE indicator will light yellow when the total lamp used time (Corresponding value) reaches 3,000<br />

hours. This is to indicate that lamp replacement is required.<br />

The total lamp used time is calculated by using the below expression,<br />

Total lamp used time (Corresponding value) = Teco + (Tnormal x 1.2) + (Thigh x 1.5)<br />

Teco: used time in the Eco mode<br />

Tnormal : used time in the Normal mode<br />

Thigh : used time in the High mode<br />

You can check the lamp used time following to the below procedure.<br />

1 Press and hold the ON/STAND-BY button on the projector for more than 20 seconds.<br />

2 The projector used time and lamp used time will be displayed on the screen briefly as follows.<br />

Projector used time<br />

Counter<br />

Projector<br />

Lamp<br />

High<br />

Normal<br />

Eco<br />

Corresponding value<br />

750 H<br />

200 H<br />

250 H<br />

300 H<br />

900 H<br />

Total lamp used time<br />

--