Troubleshooting<br />
No Power<br />
This projector provides a function which can be specified a defective area simply by indicating the LEDs. Connect the<br />
AC cord and press the Power button once and then check the LED indication.<br />
- When all of LED indicators are not lighting, the symptom indicates that the primary power supply circuit does<br />
not operate properly. Check the power primary circuit and parts as follow;<br />
AC cord, F601 (Fuse), Power board,<br />
SW902 (Thermal sw.) short in normal<br />
SW902 opens when the surrounding temperature of the switch exceeds 100°C.<br />
- When the WARNING (red) and POWER(red) indicators are flashing, the symptom indicates that the projector<br />
detected an abnormal temperature risen inside the projector. Check the air filters and remove the object near the<br />
intake and exhaust fan openings, and wait until the POWER indicator stops flashing, and then try to turn on the<br />
projector.<br />
The internal temperature is monitored by sensor ICs, IC8811(Lamp), IC8821 (Panel) on the Main board and<br />
IC4831 (Room) on the Temp. board<br />
- When the WARNING indicator lights red, the symptom indicates that the projector detected an abnormality in<br />
the cooling fan operation or in the power supply secondary circuits. Check fan operation and power supply lines,<br />
and the driving signal status.<br />
The P_FAIL signal (Error: L) is sent to pin 215 of IC301 when the abnormality occurres inside the<br />
projector, and then the IC301 sends the shutdown signal, LAMPDC_ON, to the power supply circuit to stop its<br />
operation, and signal BALAST_AC to the lamp ballast board via IC4891 and SW901 to stop<br />
operation of the lamp circuit.<br />
An abnormality occurs on the secondary power supply;<br />
Check power supplies 15.5V, S6V, S-5V. P_FAIL signal be<strong>com</strong>es “Low” when the abnormality occurs on<br />
any of the power supply lines.<br />
An abnormality occurs on the fan control circuit;<br />
Check FN901, FN902, FN903, FN904, FN905, FN907 and peripheral circuit.<br />
If any of the fans has an error, the fan lock signal drives Q3601 or Q3644 be<strong>com</strong>es on. As the result, signal<br />
FAN_ERR be<strong>com</strong>es Low and is sent to lamp ballast board to stop lamp circuit.<br />
An abnormality occurs on the drive signals;<br />
ON_150V signal (Power-on: H) is output from pin 344 of IC301 and switches Q2501,15.5V supply circuit.<br />
ON_5VA signal (Power-on: H) is output from pin 110 of IC301 and switches Q3582, 5VA supply circuit and<br />
switches IC5081, 5V_AUDIO supply circuit. ON_3.3V signal (Power-on: H) is output from pin 11 of IC301<br />
and switches IC5631, 3.3V supply circuit and IC491, 1.2V supply circuit.<br />
LAMPDC_ON signal (Power-on: H) is output from pin 89 of IC301 and supplied to the P.F Control IC,<br />
IC601, on the power supply board through Q681, and PC603.<br />
BALAST_AC signal (Power-on: H) is output from pin 413 of IC301 and applied to pin 2 of IC4891 and output<br />
pin 4 and then supplied to the lamp ballast board through SW901.<br />
CHO_RXD signal at pin 26 of IC301 is applied from the lamp ballast unit. If the abnormality occurred on<br />
the lamp ballast unit, LAMP_DET/CHO_RXD signal be<strong>com</strong>es “High” and then IC301 shuts down the power<br />
supply circuit.<br />
Lamp Cover switch<br />
Make sure that the lamp cover is mounted correctly. If not<br />
or the lamp cover removed, the lamp does not light on for<br />
the safety. Check the lamp cover and lamp cover switch<br />
(SW901).<br />