Circuit Protections<br />
This projector provides the following circuit protections to operate in safety. If the abnormality occurs inside the projector,<br />
it will automatically turn off by operating one of the following protection circuits.<br />
Thermal switch<br />
There is the thermal switch (SW902) inside of the projector to detect<br />
the internal temperature rising abnormally. When the internal temperature<br />
reaches near 100˚C, the thermal switch opens to stop the<br />
operation of the power supply circuit.<br />
The thermal switch cannot be reset itself automatically even if the<br />
internal temperature be<strong>com</strong>es normal. Reset the thermal switch following<br />
to the below procedure.<br />
How to reset the thermal switch<br />
1. Insert the sharp tool like a screwdriver into a hole on the cabinet<br />
from the cabinet bottom.<br />
2. Press the reset button on the thermal switch with the screwdriver.<br />
CAUTION:<br />
Before press the reset button, make sure that the AC cord must be<br />
disconnected from the AC outlet.<br />
Thermal switch (SW902)<br />
Lamp cover switch<br />
Lamp cover switch<br />
(SW901)<br />
The lamp cover switch (SW901) cuts off the drive signal to the lamp<br />
circuit when the lamp cover is removed or not closed <strong>com</strong>pletely.<br />
After opening the lamp cover for replacing the lamp ass’y, place the<br />
lamp cover correctly otherwise the projector can not turn on.<br />
Fuse<br />
A fuse is located inside of the projector. When the POWER indicator<br />
is not lightning, the fuse may be opened. Check the fuse as following<br />
steps.<br />
The fuse should be used with the following type;<br />
Fuse<br />
Fuse Part No.: 323 025 1204<br />
TYPE 8A 250V FUSE<br />
LITTLE FUSE INC. TYPE 21500.8<br />
How to replace the fuse<br />
1. The fuse is placed on the filter board under the main board. Remove<br />
the cabinet top and main board.<br />
2. Take the fuse off, and replace the new one with the specified type.<br />
--