Electrical Adjustments<br />

Group/<br />

Item Item Name Function Initial Range Note<br />

14 Temp C-A Warning (Eco)<br />

Temp. C-A to judge the Temp Error at Normal<br />

(Clogging Det.)<br />

100 100 100 100 0-100<br />

15 Temp A Warning Offset (Temp) Offset of Temp Error (Temp.)<br />

5 0-100<br />

16 Temp B Warning Offset (Temp) Error Setting Value is increased XC at the<br />

5 0-100<br />

17 Temp C Warning Offset (Temp)<br />

below condition<br />

* Standby<br />

15 0-100<br />

18 Temp B-A Warning Offset (Temp) * Right to turn on the lamp<br />

0 0-100<br />

19 Temp C-A Warning Offset (Temp) *Right to change the Lamp mode<br />

0 0-100<br />

20 Temp A Warning Offset (Time) Offset of Temp Error (Minutes)<br />

5 0-100<br />

21 Temp B Warning Offset (Time) Error Setting Value is increased X minute at<br />

5 0-100<br />

22 Temp C Warning Offset (Time)<br />

the below condition<br />

* Standby<br />

18 0-100<br />

23 Temp B-A Warning Offset (Time) * Right to turn on the lamp<br />

1 0-100<br />

24 Temp C-A Warning Offset (Time) *Right to change the Lamp mode<br />

1 0-100<br />

25 Factory Mode For factor use 0 0-1<br />

Group 254 Fan Control Range Setting (Temp./Voltage) Normal Ceiling<br />

-40-<br />

HiLand-<br />

Normal<br />

HiLand-<br />

Ceiling<br />

0 High Fan Control Min Temp<br />

40 40 44 44 20-100<br />

Temp Senser Control Start/End Temp. at High<br />

1 High Fan Control Max Temp 46 46 44 44 20-100<br />

2 High Fan1 Min<br />

75 75 135 135 0-255<br />

3 High Fan1 Max 135 135 135 135 0-255<br />

4 High Fan2 Min 85 85 130 130 0-255<br />

5 High Fan2 Max 130 130 130 130 0-255<br />

Fan voltage value at High (unit: 0.1V)<br />

6 High Fan3 Min 75 80 80 85 0-255<br />

7 High Fan3 Max 80 85 80 85 0-255<br />

8 High Fan4 Min 9999 9999 -<br />

9 High Fan4 Max 9999 9999 -<br />

10 Normal Fan Control Min Temp Temp Senser Control Start/End Tem.p at 40 40 44 44 20-100<br />

11 Normal Fan Control Max Temp Normal<br />

46 46 44 44 20-100<br />

12 Normal Fan1 Min<br />

67 67 125 125 0-255<br />

13 Normal Fan1 Max 125 125 125 125 0-255<br />

14 Normal Fan2 Min 75 75 120 120 0-255<br />

15 Normal Fan2 Max 120 120 120 120 0-255<br />

Fan voltage value at Normal (unit: 0.1V)<br />

16 Normal Fan3 Min 70 65 75 70 0-255<br />

17 Normal Fan3 Max 75 70 75 70 0-255<br />

18 Normal Fan4 Min 9999 9999 -<br />

19 Normal Fan4 Max 9999 9999 -<br />

20 Eco Fan Control Min Temp<br />

38 38 44 44 20-100<br />

Temp Senser Control Start/End Tem.p at Eco<br />

21 Eco Fan Control Max Temp 44 44 44 44 20-100<br />

22 Eco Fan1 Min<br />

57 57 115 115 0-255<br />

23 Eco Fan1 Max 115 115 115 115 0-255<br />

24 Eco Fan2 Min 70 70 110 110 0-255<br />

25 Eco Fan2 Max 110 110 110 110 0-255<br />

Fan voltage value at Eco (unit: 0.1V)<br />

26 Eco Fan3 Min 55 55 55 55 0-255<br />

27 Eco Fan3 Max 55 55 55 55 0-255<br />

28 Eco Fan4 Min 9999 9999 -<br />

29 Eco Fan4 Max 9999 9999 -<br />

Group 255 Fan Start/Cooling Setting<br />

0 Fan1 Initial Volt<br />

70 0-255<br />

1 Fan2 Initial Volt 70 0-255<br />

Fan Start Voltage (0.1V)<br />

2 Fan3 Initial Volt 70 0-255<br />

3 Not used 9999 -<br />

4 Fan1 Cooling Speed Fan Voltage at Power Off (0.1V) 130 0-255<br />

5 Fan2 Cooling Speed 130 0-255<br />

6 Fan3 Cooling Speed 130 0-255<br />

7 Not used 9999 -<br />

8 Cooling Time L1<br />

Cooling Time stting at Fan Mode L1 (x 30 sec)<br />

1: 30, 3: 90, 15: 450 sec.<br />

2 1-15<br />

9 Cooling Time L2<br />

Cooling Time stting at Fan Mode L2 (x 30 sec)<br />

1: 30, 3: 90, 15: 450 sec.<br />

3 1-15<br />

10 Temp Error Cooling Time Cooling Time setting at Temp Erro (x 30 sec) 3 1-15<br />

11 OnStart Cooling Start Threshold 38 0-100<br />

12 After shutdown cooling Cooling after shutdown (0: No, 1: Yes) 1 0-1<br />

Group 256 Fan Lamp Voltage Down Setting<br />

0 Lamp Voltage Current Lamp Voltage (0.1V)(Read only) - 0-255<br />

1 Lamp Vol Threshold<br />

Threshold to judge Lamp Voltage Down ( V×<br />

10)<br />

30-90