Section 3 - IEEE-488 STD (GPIB) Programming<br />

3.3.4 Examples<br />

3.3.4.1 Example 1<br />

To set both channels to 10dB input gain, 2kHz, 0dB output gain:<br />

AL; 10IG;2K;0OG <br />

NOTE<br />

It is only necessary to send those parameters<br />

that change, all others remain unaffected.<br />

3.3.4.2 Example 2<br />

To change frequency to 150Hz:<br />

150H<br />

or 150bHZ†<br />

or 150F<br />

or .15K<br />

or F150<br />

or H150<br />

or HZ150<br />

or K0.15<br />

or 1.5E2HZ<br />

or F1.5E2<br />

3.3.4.3 Example 3<br />

To read back the settings of channel 2 (see Section 3.5.1):<br />

Data sent to filter: CH2<br />

Data received from filter † :10b2.000E+3b02b00bAC*<br />

Interpretation:<br />

10dB input gain<br />

2kHz cutoff frequency<br />

channel #2<br />

0dB output gain<br />

ac coupled<br />

all channel mode (indicated by the “*”)<br />