02.01.2015 Views

6600 - Krohn-Hite Corporation

6600 - Krohn-Hite Corporation

6600 - Krohn-Hite Corporation

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MODEL <strong>6600</strong><br />

OPERATING and MAINTENANCE<br />

MANUAL<br />

! I --­ I<br />

I I<br />

•<br />

10Hz to 10MHz<br />

PRECISION PHASEMETER


SERVICE AND WARRANTY<br />

KR OHN-HITE Instruments ar e designed and manufactured in accordance with sound<br />

engineering practices and should giue long trouble-free service under normal op erating<br />

conditions. IJ your Instrument Jails to provide satisfactory service and you are unable to<br />

locate th e source oj trouble, contact our Representative if th ere is one in your area or write<br />

to our Service Department gl'ving all the inform ation available concerning theJa ilure.<br />

Do not return th e instrument unthout our written a uthorization [or, in most cases, we<br />

will be able to supply you with the information necessary to repair the instrument and thus<br />

auoid the transportation problems and costs . When it becomes necessary to return the<br />

instrumen t to our Factory, kindly pack it careJully and ShlP it to us prepaid .<br />

All KROHN-HITE products are warranted against defectiue materials and<br />

ioorkmansliip, This warranty ap-plies Jor a period oj one year Jrom the date oj dehvery to<br />

the original purchaser. Any instrument that is found within th e on e year period not to m eet<br />

th ese standards, will be repaired or replaced. This warranty does not apply to elec tron<br />

tubes, [uses, or batteries. No other warranty 15 exp ressed or im-plied.<br />

KROHN-HITE CORPORATION reserves th e right to make design change s at any time<br />

unthout in curring any obligation to incorporate these changes in instruments previously<br />

purchased.<br />

Modifications to this instrument must not be made without the umt t eri consen t oj an<br />

authorized em ployee ojKROHN-HITE CORPORATION.


1Hz TO 10MHz<br />

PRECISION PHASEMETER<br />

MODEL <strong>6600</strong><br />

Serial No.<br />

- - --<br />

OPERATING AND MAl TE ANCE<br />

MANUAL<br />

K OHN-HITE CORPORATION<br />

han Drive, 9<br />

Brockton , MA 02301-5566<br />

Tel : (508) 580-1660 ; Fax: (508) 583-8989<br />

E-Mail: info@krohn-hite.com; Webs ite: www.krohn-h ite.com


Model <strong>6600</strong><br />

Table of Contents<br />

TABLE OF CO TENTS<br />

SECTI ON<br />

PAGE<br />

1.0 GENERAL DESCRIPTION. 1-1<br />

1. 1 Introduction. . 1-1<br />

1 . 2 Specif ications . 1-1<br />

1 . 3 Typical Performance 1-3<br />

1 . 4 Factors Affecting Phasemeter Accuracy 1 -4<br />

1.4.1 Inconsistencies In Meter Reading Near 1-4<br />

1.4.2 Noi se Present On The Input Signal s . . . 1-4<br />

1.4 . 3 Distortion Present On The I nput Signal s . 1 - 5<br />

2.0 OPERATION . 2- 1<br />

2 . 1 Introduction . 2- 1<br />

2 . 2 Power Requirements . 2-1<br />

2.3 Int r oduc t i on . . . . 2-1<br />

2 .4 Front Panel Controls, Connectors and I ndi c a t or s 2- 2<br />

2 . 5 Rear Panel Cont rols and Connectors. 2- 3<br />

2. 6 Oper ati on .. 2- 3<br />

3.0 DIGITAL INTERFACE . 3- 1<br />

3 . 1 BCD Option . . 3-1<br />

3 . 2 Out put Connector Pin Connections. 3- 1<br />

4.0 INCOM ING ACCEPTANCE. . . . . 4-1<br />

4 . 1 Introduction . 4-1<br />

4 .2 Test Equi pment Required 4 - 1<br />

4. 3 Proc edur e . 4 - 2<br />

4.3 .1 Display Calibration. 4 - 2<br />

4. 3 . 2 Low Frequency Sinewave Check 4 - 2<br />

4.3.3 High Frequency Sinewave Check. 4 - 2<br />

4 .3.4 Quadrature Low Frequency Check 4- 2<br />

4 . 3 . 5 Balanced High Frequency Sinewave Check 4 - 3<br />

4 .3.6 Balanced Low Frequency Sinewave Check. 4 - 3<br />

4 .3 .7 Balanced High Frequency Squarewave Check 4 - 3<br />

4 .3.8 Analog Output Check . 4 -4<br />

4 .3.9 BCD Output Check (optional) . 4-4<br />

i


Illustration<br />

Model <strong>6600</strong><br />

Figure 1<br />

Model <strong>6600</strong> Precision Phasemeter<br />

iii

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!