PERFORMANCE DATA TABLES<br />
Triple Insulating Double Coated Low-E (Air Filled)<br />
The performance data applies to triple insulating glass units with three plies (clear lites unless otherwise specified) of 1/4"<br />
(6mm) glass and two 1/2" (13.2mm) airspaces or argon spaces. The coating is applied to the second (#2) surface. If double coated,<br />
a VE-85 coating is applied to the fourth (#4) surface.<br />
The solar and optical data presented in this guide is center-of-glass data based on the National Fenestration Rating Council<br />
measurement standards. They were calculated using Lawrence Berkeley National Laboratory’s (LBNL) WINDOW 5.2/6.3 software.<br />
In some cases performance data changed in comparison to previous versions of LBNL’s WINDOW program.<br />
Product Transmittance Reflectance U-Value<br />
Visible Solar U-V Exterior Interior Solar Winter Summer<br />
Shading<br />
Coefficient<br />
Relative<br />
Heat Gain<br />
VE 1-85 65% 33% 12% 16% 16% 23% .17 .17 .51 104 .44 1.48 0.9<br />
VE 1-2M 60% 26% 5% 14% 16% 32% .16 .16 .37 77 .32 1.88 0.8<br />
VE 1-52 43% 23% 10% 17% 15% 21% .17 .17 .36 75 .31 1.39 0.9<br />
VE 1-48 40% 21% 9% 18% 15% 23% .17 .17 .34 71 .30 1.33 0.9<br />
VE 1-42 32% 17% 8% 20% 17% 22% .17 .17 .28 59 .25 1.28 0.9<br />
VRE 1-59 45% 21% 8% 32% 21% 39% .16 .16 .32 67 .28 1.61 0.8<br />
VRE 1-54 41% 19% 8% 33% 19% 38% .16 .17 .29 61 .25 1.64 0.8<br />
VRE 1-46 37% 18% 7% 35% 18% 40% .16 .16 .27 57 .24 1.54 0.8<br />
VRE 1-38 31% 14% 6% 45% 23% 47% .16 .16 .22 47 .19 1.63 0.8<br />
VRE 1-30 24% 11% 5% 48% 18% 47% .16 .16 .18 39 .16 1.50 0.8<br />
VNE 1-63 53% 20% 2% 12% 15% 38% .16 .16 .28 59 .25 2.12 0.8<br />
VUE 1-50 42% 16% 3% 12% 15% 27% .16 .16 .25 51 .21 2.00 0.8<br />
SHGC<br />
LSG<br />
European<br />
U-Value<br />
Triple Insulating Double Coated Low-E (Argon Filled)<br />
Product Transmittance Reflectance U-Value<br />
Visible Solar U-V Exterior Interior Solar Winter Summer<br />
Shading<br />
Coefficient<br />
Relative<br />
Heat Gain<br />
VE 1-85 65% 33% 12% 16% 16% 23% .14 .14 .51 104 .44 1.48 0.7<br />
VE 1-2M 60% 26% 5% 14% 16% 32% .13 .13 .37 76 .32 1.88 0.7<br />
VE 1-52 43% 23% 10% 17% 15% 21% .14 .14 .36 74 .31 1.39 0.7<br />
VE 1-48 40% 21% 9% 18% 15% 23% .14 .14 .34 70 .29 1.38 0.7<br />
VE 1-42 32% 17% 8% 20% 17% 22% .14 .14 .28 58 .24 1.33 0.7<br />
VRE 1-59 45% 21% 8% 32% 21% 39% .13 .13 .32 66 .28 1.61 0.7<br />
VRE 1-54 41% 19% 8% 33% 19% 38% .13 .13 .29 60 .25 1.64 0.7<br />
VRE 1-46 37% 18% 7% 35% 18% 40% .13 .13 .27 56 .23 1.61 0.7<br />
VRE 1-38 31% 14% 6% 45% 23% 47% .13 .13 .22 46 .19 1.63 0.7<br />
VRE 1-30 24% 11% 5% 48% 18% 47% .13 .13 .18 38 .15 1.60 0.7<br />
VNE 1-63 53% 20% 2% 12% 15% 38% .13 .13 .28 58 .24 2.21 0.7<br />
VUE 1-50 42% 16% 3% 12% 15% 27% .13 .13 .24 50 .21 2.00 0.7<br />
SHGC<br />
LSG<br />
European<br />
U-Value<br />
<strong>VIRACON</strong> // INSULATING GLASS<br />
075