Specification Example<br />

Recommended Architectural<br />

Glass Specification<br />

The specification on the following pages is written according to the Construction Specifications Institute (CSI) 3-Part Format. The<br />

specification can be customized for your project by including details for the products you are specifying in Article 2.6 Product<br />

Schedule. The blue text below is intended to be altered to identify the specific product you selected.<br />

Please see example below<br />

Step 1. Select a product: For Example - VRE6-54 Insulating Glass.<br />

Step 2. Find the product type in Article 2.6 Product Schedule.<br />

a. Insulating Coated Glass:<br />

1. {Overall Thickness} {Product Number, ex: VRE1-46} Insulating Coated Glass as manufactured by Viracon.<br />

a. Exterior Glass Ply: {Thickness} {Color} {Heat Treatment - AN, HS or FT}<br />

b. Coating: {Coating} on #2 Surface<br />

c. Space: {Thickness} {Material – aluminum, stainless steel, etc.} {finish – mill finish or black painted}<br />

{Gas – argon or air} filled<br />

d. Silicone: {gray or black}<br />

e. Interior Glass Ply: {Thickness} {Color} {Heat Treatment - AN, HS or FT}<br />

2. Performance Requirements<br />

a. Visible Light Transmittance: { }%<br />

b. Exterior Reflectance: { }%<br />

c. Winter U-Value: { }<br />

d. Summer U-Value: { }<br />

e. Shading Coefficient: { }<br />

f. Solar Heat Gain Coefficient: { }<br />

g. Light to Solar Gain Ratio: { }<br />

Step 3. Insert VRE6-54 into your specification including all of the details needed to manufacture the glass unit as well as the solar<br />

performance requirements.<br />

a. Insulating Coated Glass:<br />

1. 1” VRE6-54 Insulating Coated Glass as manufactured by Viracon.<br />

a. Exterior Glass Ply: 1/4” Blue-green HS<br />

b. Coating: VRE-54 on #2 Surface<br />

c. Space: 1/2” – aluminum, black painted, air filled<br />

d. Silicone: black<br />

e. Interior Glass Ply: 1/4” Clear HS<br />

2. Performance Requirements<br />

a. Visible Light Transmittance: 41%<br />

b. Exterior Reflectance: 24%<br />

The information in the Architectural Glass Specification on pages<br />

c. Winter U-Value: 0.30<br />

110-123 is offered to assist in specifying Viracon’s Fabricated<br />

d. Summer U-Value: 0.27<br />

Glass Products. Viracon does not assume any responsibility for<br />

e. Shading Coefficient: 0.29<br />

the adequacy of this specification for a particular application. The<br />

f. Solar Heat Gain Coefficient: 0.25<br />

design professional must confirm applicable code and design.<br />

g. Light to Solar Gain Ratio: 1.63<br />