<strong>Sensys</strong> <strong>Stud</strong> <strong>Trial</strong><br />

3. <strong>Trial</strong> Details<br />

3.1 <strong>Trial</strong> Site<br />

The Penrose Travel Demand management (TDM) loop site has been chosen for this trial<br />

because it has a signal controller that is currently connected to inductive loops allowing a<br />

comparison with the contact closure outputs from the <strong>Sensys</strong> system. There is also an<br />

Ethernet switch present for connection back at the central system to output the speed,<br />

occupancy, classification and count data.<br />

The site also has an existing pole for the access point, cabinet for the contact closure rack<br />

and has good access from the motorway with a parking area behind barriers.<br />

3.2 Equipment List<br />

The following equipment was used for the trial:<br />

Item<br />

Qty<br />

<strong>Sensys</strong> AP240 Wireless Access Point 1<br />

<strong>Sensys</strong> VSN240 Wireless Sensors 6<br />

<strong>Sensys</strong> CC Master Contact Closure Card (4 Outputs) 1<br />

<strong>Sensys</strong> EX Expansion Contact Closure Card (4 Outputs) 1<br />

<strong>Sensys</strong> Access Box 1<br />

Traffic Controller (Type 170, NEMA TS1, NEMA TS2, or Type 2070) 1<br />

Software to be Installed at Traffic Centre 1<br />

Fixings for Access Point and Traffic Controller<br />

As required<br />

8 Core Feeder Cable (Contact Cards to Signal Controller) 30m Approx<br />

Cat 6 Cable (Between Wireless Access Point and Access Box)<br />

Cat 6 Cable (Between Access Box and Contact Closure Card)<br />

Cat 6 Cable (Between Master Contact Card and Expansion)<br />

Cat 6 Cable (Between Access Box and Ethernet Switch)<br />

External Conduit for Cables as Required<br />

Miscellaneous fixings, looms and cable ties as required<br />

30m Approx<br />

1m<br />

1m<br />

1m<br />

30m Approx<br />

As required<br />