<strong>Sensys</strong> <strong>Stud</strong> <strong>Trial</strong><br />
Occupancy<br />
The average occupancy for these times over all 3 lanes are shown below.<br />
07:00 – 09:00<br />
Inductance <strong>Sensys</strong> Difference<br />
Lane 1 15.26% 14.90% 0.36<br />
Lane 2 14.18% 15.53% 1.35<br />
Lane 3 11.50% 9.74% 1.76<br />
NB: These results have been discounted as the countss are far too low for this time period so<br />
there was an error with either SCATS or the data collection.<br />
11:30 – 13:30<br />
Inductance <strong>Sensys</strong> Difference % Difference<br />
Lane 1 3.44% 3.74% 0.3 8.02%<br />
Lane 2 3.67% 3.97% 0.3 7.56%<br />
Lane 3 3.03% 3.22% 0.19 5.90%<br />
15:30 – 17:30<br />
Inductance <strong>Sensys</strong> Difference % Difference<br />
Lane 1 5.63% 5.94% 0.31 5.22%<br />
Lane 2 5.72% 6.07% 0.35 5.77%<br />
Lane 3 5.96% 6.43% 0.47 7.31%<br />
22:30 – 00:00<br />
Inductance <strong>Sensys</strong> Difference % Difference<br />
Lane 1 0.88% 0.94% 0.06 6.38%<br />
Lane 2 1.13% 1.21% 0.08 6.61%<br />
Lane 3 0.51% 0.53% 0.02 3.77%<br />
Commercial in Confidence Page 34