<strong>Sensys</strong> <strong>Stud</strong> <strong>Trial</strong><br />
5.1 First Set of Results<br />
Count and Occupancy data was collected and compared on SCATS between the Induction<br />
Loops and the <strong>Sensys</strong> studs for the following peak and off peak times, the results are shown on<br />
the following 2 pages.<br />
07:00 – 09:00 (Peak AM) 4 th July<br />
11:30 – 13:30 (Off Peak AM) 4 th July<br />
15:30 – 17:30 (Peak PM) 4 th July<br />
22:30 – 00:00 (Off Peak PM) 4 th July<br />
The detail from these tests can be found in Appendix A<br />
Analysis<br />
The count for the morning peak (07:00 – 09:00 ) showed strange results for the count data. The<br />
counts recorded by both the inductive loops and <strong>Sensys</strong> studs were far below what would be<br />
expected for this time of day and therefore it was concluded that there was either an error with<br />
SCATS or the data collection during this time period, therefore these results have been<br />
discounted.<br />
The count average for these results gives a difference of 2.07%<br />
Time Period Difference % Difference<br />
11.30 - 13.30 -195 2.22%<br />
15.30 - 17.30 -120 1.20%<br />
22.30 - 00.00 -53 2.80%<br />
Average 2.07%<br />
The occupancy average for these results gives a difference of 6.28%<br />
Time Period Difference in % % Difference<br />
11.30 - 13.30 0.79 7.16%<br />
15.30 - 17.30 1.13 6.10%<br />
22.30 - 00.00 0.16 5.59%<br />
Average 6.28%<br />