<strong>Sensys</strong> <strong>Stud</strong> <strong>Trial</strong><br />

5.1 First Set of Results<br />

Count and Occupancy data was collected and compared on SCATS between the Induction<br />

Loops and the <strong>Sensys</strong> studs for the following peak and off peak times, the results are shown on<br />

the following 2 pages.<br />

07:00 – 09:00 (Peak AM) 4 th July<br />

11:30 – 13:30 (Off Peak AM) 4 th July<br />

15:30 – 17:30 (Peak PM) 4 th July<br />

22:30 – 00:00 (Off Peak PM) 4 th July<br />

The detail from these tests can be found in Appendix A<br />

Analysis<br />

The count for the morning peak (07:00 – 09:00 ) showed strange results for the count data. The<br />

counts recorded by both the inductive loops and <strong>Sensys</strong> studs were far below what would be<br />

expected for this time of day and therefore it was concluded that there was either an error with<br />

SCATS or the data collection during this time period, therefore these results have been<br />

discounted.<br />

The count average for these results gives a difference of 2.07%<br />

Time Period Difference % Difference<br />

11.30 - 13.30 -195 2.22%<br />

15.30 - 17.30 -120 1.20%<br />

22.30 - 00.00 -53 2.80%<br />

Average 2.07%<br />

The occupancy average for these results gives a difference of 6.28%<br />

Time Period Difference in % % Difference<br />

11.30 - 13.30 0.79 7.16%<br />

15.30 - 17.30 1.13 6.10%<br />

22.30 - 00.00 0.16 5.59%<br />

Average 6.28%<br />