<strong>HZB12</strong>-<strong>60T</strong><br />
<strong>HZB12</strong>-<strong>60T</strong> Valve Regulated Lead Acid battery.<br />
15 year design life for stand by power applications.<br />
12 Volts 60 Ah<br />
Innovative Features<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Specifications<br />
Nominal Voltage<br />
Nominal Capacity<br />
Design Life<br />
Operating Temperature<br />
Grid alloy<br />
Plates<br />
Separator<br />
Active material<br />
Case and cover<br />
Charge Voltage<br />
Electrolyte<br />
Completely maintenance<br />
free, sealed construction<br />
eliminates the need for<br />
watering<br />
Fully tank formed plates<br />
Analytical Grade electrolyte<br />
Spill proof / leak proof<br />
Valve regulated Max internal<br />
pressure 2.5 psi<br />
Multi-position usage<br />
ABS Case and cover - V0 on<br />
request<br />
Low self discharge<br />
FAA and IATA approved as<br />
non-hazardous<br />
Built to comply with IEC 896-<br />
2, DIN 43534, BS 6290 Pt4,<br />
Eurobat.<br />
12 Volts<br />
60Ah<br />
15 Years<br />
° °<br />
-20 C to 50 C<br />
Calcium / Tin lead alloy<br />
Flat Pasted<br />
Absorbant Glass Mat<br />
Very high purity lead<br />
ABS (VO on request)<br />
° °<br />
Float 2.25 - 2.30 VPC @25 C Cycliing 2.4 @25 C<br />
Max. 2.4 VPC Max ripple 0.05C (A)<br />
Sulphuric acid Analytical grade purity<br />
Venting Valve EPDM Rubber 1.5 to 2 psi (10.5 - 14 KPa) release pressure. Resealing at 1<br />
psi (7 KPa)<br />
Terminal<br />
Insert 14mm Dia M6 thread. Epoxy sealed by extended mechanical paths<br />
Torque setting<br />
The recommended torque value for all types is 5-7 Nm<br />
Cables<br />
Connectors, cables, terminal covers on request.<br />
Sealed Lead Acid 12 Volt Bloc AGM Range<br />
PRODUCT SHEET <strong>HZB12</strong>-<strong>60T</strong><br />
LEAD LEAD<br />
RECYCLE<br />
RETURN RETURN<br />
RUBBISH BIN<br />
Pb<br />
Haze Battery Company keenly<br />
encourages environmental<br />
awareness; PLEASE follow<br />
guidelines for the recycling<br />
/disposal of lead.<br />
Website: www.hazebattery.com<br />
E mail : sales@hazebattery.com<br />
12V<br />
AGM
Specifications<br />
Nominal Voltage<br />
12V<br />
120 mm<br />
40 mm<br />
Nominal Capacity<br />
51 Ah<br />
Total Height 260 mm 10.24 inches<br />
(Inc. terminals) n/a mm n/a inches<br />
Dimensions<br />
Length 220 mm 8.66 inches<br />
Width 121 mm 4.76 inches<br />
244 mm<br />
Weight 18.5 Kg 40.9 lbs<br />
Characteristics<br />
20 hour rate<br />
53.1 Ah<br />
10 hour rate<br />
51.1 Ah<br />
Capacity<br />
5 hour rate<br />
49.1 Ah<br />
219 mm<br />
20 o C (68 o F)<br />
To 1.8 volts<br />
1 hour rate<br />
15 min rate<br />
39.4 Ah<br />
27.9 Ah<br />
Internal Resistance<br />
4.5 mOhms<br />
Impedance<br />
900 S<br />
Capacity correction for<br />
Temperature Variations<br />
(C20)<br />
40 oC (104 oF)<br />
20 oC (68 oF)<br />
0 oC (32 oF)<br />
-15 oC (5 oF)<br />
102%<br />
100%<br />
85%<br />
65%<br />
250 mm<br />
Self-Discharge<br />
20 o C (68 o F)<br />
Capacity after 1 months storage<br />
Capacity after 3 months storage<br />
Capacity after 6 months storage<br />
98%<br />
94%<br />
86%<br />
R3<br />
Short Circuit Current<br />
20 o C (68 o F)<br />
1300<br />
Terminal<br />
Charging<br />
(Constant Voltage)<br />
Standard<br />
Optional<br />
Cyclic<br />
Float<br />
14mm Insert M6 thread<br />
Cu Flag<br />
2.35 - 2.40 VPC (20-25 oC)<br />
2.27 - 2.30 VPC (15-25 oC)<br />
30.5 mm<br />
21<br />
R4<br />
2-M6<br />
120 mm<br />
219 mm<br />
Constant Power Discharge - Watts per Cell @20 o C<br />
End V per<br />
Cell<br />
1.85 305 234 189 155 134 119 107 97.9 91.4 76.0 55.2 42.8 29.4 22.5<br />
1.80 335 248 201 167 142 124 112 102 94.8 77.1 56.7 44.2 30.3 23.3<br />
1.75 358 257 206 170 145 126 114 104 96.2 78.3 57.7 45.2 31.0 23.8<br />
1.70 373 264 211 174 147 129 115 105 97.5 79.8 58.7 45.9 31.7 24.7<br />
1.65 391 272 216 175 148 130 117 107 98.7 81.1 59.9 46.8 32.2 -<br />
1.60 411 282 220 178 151 132 118 108 99.5 81.9 60.6 47.5 32.7 -<br />
Constant Amps Discharge - Amps @20 o C<br />
End V per<br />
Cell<br />
5M 10M 15M 20M 25M 30M 35M 40M 45M 60M 90M 2 hr 3 hr 4 hr<br />
5M 10M 15M 20M 25M 30M 35M 40M 45M 60M 90M 2 hr 3 hr 4 hr 5 hr 8 hr 10 hr 12 hr 20 hr<br />
1.85 180 123 102 82.7 70.3 60.9 54.0 48.6 45.0 37.7 28.0 22.0 15.4 11.7 9.6 6.1 5.0 4.2 2.6<br />
1.80 200 135 112 89.9 75.2 65.5 58.0 52.1 47.9 39.4 28.6 22.4 15.7 12.0 9.8 6.3 5.1 4.3 2.7<br />
1.75 209 140 115 94.3 78.3 67.7 59.8 53.4 48.9 40.6 29.3 22.7 15.9 12.3 10.1 6.5 5.2 4.4 2.7<br />
1.70 212 142 117 95.4 79.0 68.9 60.6 54.2 49.5 41.3 29.7 23.1 16.2 12.5 10.3 6.6 5.3 4.4 2.8<br />
1.65 215 144 119 96.3 80.0 69.6 61.3 55.0 50.3 41.8 30.0 23.4 16.4 - - - - - -<br />
1.60 217 145 120 97.2 80.7 70.2 61.9 55.4 50.8 42.1 30.3 23.6 16.5 - - - - - -<br />
Ampere Hour @20 o C<br />
End V per<br />
Cell<br />
2 hr 3 hr 4 hr 5 hr 8 hr 10 hr 12 hr 20 hr<br />
1.85 43.9 46.1 46.8 48.1 49.1 50.1 50.0 52.2<br />
1.80 44.8 47.2 48.2 49.1 50.2 51.1 51.3 53.1<br />
1.75 45.4 47.7 49.1 50.3 51.7 52.2 52.3 54.4<br />
1.70 46.3 48.7 49.9 51.5 52.6 53.5 53.2 55.3<br />
1.65 46.8 49.2 - - - - - -<br />
1.60 47.3 49.6 - - - - - -<br />
R<br />
UL Recognised<br />
Component<br />
MH28512<br />
Germany<br />
EMC<br />
tested