Loss/Length Method<br />
When Loss/Length Method is selected, the <strong>WireScope</strong> <strong>350</strong> calculates<br />
the limit based on the length of the cable tested. You can set values for<br />
connectors, loss per connector, splices, and loss per splice. The<br />
connector and splice losses are ad<strong>de</strong>d to the loss that is calculated by<br />
multiplying the length of the fiber by the loss/Km specification of the<br />
selected cable, which is shown at the bottom of the Setup screen.<br />
When you select Loss/Length Method and press Next on the Loss<br />
Limit Setup screen, the screen changes to the following:<br />
1 To set any of the variable values, press the variable. The numeric<br />
keypad opens.<br />
2 Press the backspace arrow to erase the displayed value, then enter<br />
the new variable value. Press OK. The keypad closes.<br />
3 Press OK. The Fiber Autotest Settings screen displays.