5 Select the performance gra<strong>de</strong> of the connector, if known, and press<br />

OK. The Autotest Setup screen displays, with the new connector type<br />

nest to the connector icon.<br />

Choosing the Cable Pairing Convention<br />

To i<strong>de</strong>ntify the correct pair in the test results, the <strong>WireScope</strong> must be<br />

told what cable pairing convention is used. For example, if the 3,6 pair<br />

fails a test, it would be “Pair 2” if using T568A pairing, but it would be<br />

“Pair 3” if using T568B pairing.<br />

1 On the Autotest Setup screen, press Cable Pairing, then press Edit.<br />

The Cable Pairing Setup screen displays.<br />

2 Press the cable pairing convention used on the job, then press OK.<br />

The Autotest Setup screen displays, with the cable pairing convention<br />

named.<br />