Test Progress and Result Indicators<br />

��������������<br />

����������������<br />

Progress: The Progress LEDs show approximately how much of the<br />

current test is complete, 1/3, 2/3, and complete.<br />

Pass/Fail: The Pass/Fail indicator turns green when the test passes, or<br />

red when the test fails.<br />

Diagnostics<br />

The Diagnostics section of the DualRemote <strong>350</strong> front panel provi<strong>de</strong>s<br />

more <strong>de</strong>tailed information about failing test results.<br />

WS and DR: Indicate at which end of the tested cable the measurement<br />

failed.<br />

• WS lights when a failure occurs at the <strong>WireScope</strong> end of the<br />

circuit.<br />

• DR lights when a failure occurs at the DualRemote end of the<br />

circuit.<br />

• WS and DR both light when failures occur at both ends of the<br />

circuit. To <strong>de</strong>termine which failures occurred at which end of the<br />

circuit, use the Scroll button.<br />

A column of diagnostic indicators shows <strong>de</strong>tails about the cause(s) of a<br />

test failure. The failures indicated on the DualRemote <strong>350</strong> are:<br />

Wiremap: Turns red when a fault with the cable connections is<br />

<strong>de</strong>tected.<br />

Split Pairs: Turns red when a split pair is <strong>de</strong>tected.<br />

Length/Delay/Skew: Turns red when cable length, signal <strong>de</strong>lay, or<br />

skew are outsi<strong>de</strong> the passing limits.<br />

NEXT : Turns red when near-end pair-to-pair or power sum faults are<br />

<strong>de</strong>tected.<br />

Attenuation: Turns red when attenuation is outsi<strong>de</strong> passing limits.<br />

ELFEXT : Turns red when far-end pair-to-pair or power sum faults are<br />

<strong>de</strong>tected.<br />

Return Loss: Turns red when the return signal loss exceeds passing<br />

limits.<br />

Other: Turns red when any other failing test results occur. If the cable<br />

run has multiple test failure causes, the Scroll button scrolls between<br />

diagnostic indications. The current selection blinks. The pair indicators<br />

and WS or DR indicators associated with the selected failure also blink.<br />

Power<br />

The Power LED turns green when the DualRemote <strong>350</strong> is powered on.<br />