Choosing the Connector Type<br />
��������������������������<br />
����������������������<br />
Connectors from different manufacturers have different transmission<br />
characteristics. The <strong>WireScope</strong> <strong>350</strong> compensates for those differences, if<br />
you tell it what connectors are used on the job.<br />
1 On the Autotest Setup screen, press the connector icon, then press<br />
Edit. The Connector Setup screen displays.<br />
����� ���Ã������Ã���Ã��Ã���Ã�����Ã��Ã���Ã������Ã�����Ã���Ã��������Ã��Ã���Ã����Ã�����Ã���Ã��Ã���Ã<br />
�Ã����������Ã������Ã����Ã��Ã������Ã���Ã���Ã������Ã������Ã��Ã���Ã�����Ã�����Ã��Ã���Ã<br />
����������<br />
2 Press the manufacturer of the connector, then Next. A list of that<br />
manufacturer’s connectors displays.<br />
3 Press the name of the connector, then press OK. The Autotest Setup<br />
screen displays, with the selected connector type next to the<br />
connector icon. If the connector type is not in the connector<br />
database, see Adding a new connector type, on page 3-16.<br />
Choosing the Cable Pairing Convention<br />
To i<strong>de</strong>ntify the correct pair in the test results, the <strong>WireScope</strong> must be<br />
told what cable pairing convention is used. For example, if the 3,6 pair<br />
fails a test, it would be “Pair 2” if using T568A pairing, but it would be<br />
“Pair 3” if using T568B pairing.<br />