Table 2<strong>1.</strong> Port Statistics Data Window entries (Continued)<br />

Entry<br />

Ep Connects<br />

FBusy<br />

Flow Errors<br />

FReject<br />

Invalid CRC<br />

Invalid Destination<br />

Address<br />

Link Failures<br />

LIP (AL_PD,AL_PS)<br />

LIP(F7,AL_PS)<br />

LIP(F7,F7)<br />

LIP(F8,AL_PS)<br />

LIP(F8,F7)<br />

Login Count<br />

Logout Count<br />

Long Frame Count<br />

Loop Timeouts<br />

Loss Of Sync<br />

Loop Timeouts<br />

Primitive Sequence<br />

Errors<br />

Description<br />

Number of E_Port logins.<br />

Number of class 2 and class 3 fabric busy (F_BSY) frames generated<br />

by this port in response to incoming frames. This value usually<br />

indicates a busy condition on the fabric or N_port that is<br />

preventing delivery of this frame.<br />

Number of times a frame is received and all the switch ports<br />

receive buffers are full. The normal Fabric Login exchange of<br />

flow control credit should prevent this from occurring. The<br />

frame will be discarded.<br />

Number of frames, from devices, that have been rejected. Frames<br />

can be rejected for any of a large number of reasons.<br />

Number of invalid Cyclic Redundancy Check (CRC) frames<br />

detected.<br />

Number of address identifier (S_ID, D_ID) errors. AL_PA equals<br />

non-zero AL_PA found on F_Port.<br />

Number of optical link failures detected by this port. A link failure<br />

is a loss of synchronization or loss of signal while not in the<br />

offline state. A loss of signal causes the switch to attempt to<br />

re-establish the link. If the link is not re-established, a link failure<br />

is counted. A link reset is performed after a link failure.<br />

Number of F7, AL_PS LIPs, or AL_PD (vendor specific) resets<br />

performed.<br />

This LIP reinitializes the loop. An L_port, identified by AL_PS,<br />

may have noticed a performance degradation and is trying to<br />

restore the loop.<br />

A loop initialization primitive frame that acquires an AL_PA.<br />

This LIP denotes a loop failure detected by the L_port identified<br />

by AL_PS.<br />

A loop initialization primitive frame used to indicate that a Loop<br />

Failure has been detected at its receiver and does not have a<br />

valid AL_PA.<br />

Number of device logins that have occurred on the switch.<br />

Number of device logouts that have occurred on the switch.<br />

Number of incidents in which one or more frames greater than<br />

the maximum size (2,136 bytes) are received<br />

Number of loop timeouts.<br />

Number of synchronization losses (>100 ms) detected by this<br />

port. A loss of synchronization is detected by receipt of an<br />

invalid transmission word.<br />

Number of loop timeouts.<br />

Number of bad primitives received by the port.<br />

88 <strong>IBM</strong> <strong>Flex</strong> <strong>System</strong> <strong>FC3171</strong> 8 <strong>Gb</strong> <strong>SAN</strong> <strong>Switch</strong> QuickTools User’s Guide