Table 7. <strong>Switch</strong> data window entries (Continued)<br />

Entry<br />

Discard Inactive<br />

Implicit Hard Zoning<br />

Security Auto Save<br />

Security Fabric Binding<br />

Enable<br />

Description<br />

Automatically removes the previously active zone set when<br />

a zone set is activated on a switch<br />

Introduces hardware enforcement of zoning regardless of<br />

type. All zones and all supported zone member types will<br />

have hardware enforcement.<br />

If enabled, the security configuration is saved to non-volatile<br />

memory on the switch. If disabled, the security file is<br />

saved only to temporary memory. The Auto Save feature is<br />

used when Fabric Binding is enabled. When Auto Save is<br />

disabled, any updates from remote switches will not be<br />

saved locally<br />

If enabled, it is required that the expected domain ID of a<br />

switch be verified before being allowed to attach to the fabric.<br />

Advanced Group<br />

R_A_TOV<br />

E_D_TOV<br />

Number of Donor Groups<br />

Inactivity Timeout<br />

Interop Mode<br />

Legacy Address Format<br />

In-band Enabled<br />

Principal <strong>Switch</strong><br />

Resource allocation timeout value<br />

Error detect timeout value<br />

Total number of donor port groups. A donor group is a set<br />

of ports on a switch that can donate buffer credits to each<br />

other.<br />

Number of minutes the switch waits before terminating an<br />

idle command line interface session. Zero (0) disables the<br />

time out threshold.<br />

Non-configurable. Zoning merge status. When a zone set is<br />

activated on an FC-SW-2 compliant switch, only the active<br />

zone set is propagated to all switches in the fabric. When a<br />

zone set is activated on a non-FC-SW-2 compliant switch,<br />

the active zone set and all inactive zone sets (the entire zoning<br />

database) are stored in permanent memory.<br />

Non-configurable. Legacy port addressing status. Enabled<br />

only for interoperability with non-FC-SW-2 compliant<br />

switches<br />

In-band management status. Permits (True) or prevents<br />

(False) a switch from being managed over an inter-switch<br />

link (ISL)<br />

If there is a domain ID conflict in the fabric, the switch with<br />

the highest principal priority, or the principal switch, will<br />

reassign any domain ID conflicts and establish the fabric.<br />