Table 7. <strong>Switch</strong> data window entries (Continued)<br />

Entry<br />

Embedded GUI Enabled<br />

Inactivity Timeout<br />

GUI Mgmt Enabled<br />

Telnet Enabled<br />

SSH Enabled<br />

SSL Enabled<br />

CIM Enabled<br />

SLP Enabled<br />

FTP Enabled<br />

Management Server<br />

Enabled<br />

SNMP Enabled<br />

Call Home Enabled<br />

Description<br />

QuickTools web applet status. Enables or disables the web<br />

applet on the switch<br />

Number of minutes the switch waits before terminating an<br />

idle command line interface session. Zero (0) disables the<br />

time out threshold.<br />

Web applet status. If disabled, the switch cannot be managed<br />

using the web applet.<br />

Telnet client status<br />

Secure Shell status. If enabled, an encrypted data path is<br />

provided for command line interface sessions.<br />

Secure Sockets Layer status. If enabled, encryption for<br />

switch management web applet and CIM sessions is provided.<br />

Common Information Model status. The Common Information<br />

Model (CIM) agent is based on the SNIA Storage Management<br />

Initiative Specification (SMI-S), which is the<br />

standard for <strong>SAN</strong> management in a heterogeneous environment.<br />

Service location protocol status<br />

FTP status<br />

Management server status<br />

SNMP enabled or disabled<br />

If enabled and configured, switches can send alerts and<br />

events to pagers and Email. Users can configure the type of<br />

events and where the alerts are sent.<br />

Zones/Security Group<br />

Interop Mode<br />

Legacy Address Format<br />

Merge Auto Save<br />

Zoning Default Visibility<br />

Default Zone<br />

Non-configurable. Zoning merge status. When a zone set is<br />

activated on an FC-SW-2 compliant switch, only the active<br />

zone set is propagated to all switches in the fabric. When a<br />

zone set is activated on a non-FC-SW-2 compliant switch,<br />

the active zone set and all inactive zone sets (the entire zoning<br />

database) are stored in permanent memory.<br />

Non-configurable. Legacy port addressing status. Enabled<br />

only for interoperability with non-FC-SW-2 compliant<br />

switches<br />

Zoning auto save status. Saves zoning updates in temporary<br />

memory and the zoning database (True) or only in temporary<br />

memory (False)<br />

N/A—does not apply to this switch<br />

Disables communication between ports and devices not<br />

defined in the active zone set, or when there is no active<br />

zone set<br />

46 <strong>IBM</strong> <strong>Flex</strong> <strong>System</strong> <strong>FC3171</strong> 8 <strong>Gb</strong> <strong>SAN</strong> <strong>Switch</strong> QuickTools User’s Guide