Chapter 1. IBM Flex System FC3171 8 Gb SAN Switch - QLogic
Chapter 1. IBM Flex System FC3171 8 Gb SAN Switch - QLogic
Chapter 1. IBM Flex System FC3171 8 Gb SAN Switch - QLogic
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
The <strong>Switch</strong> data window entries are listed in Table 7.<br />
Table 7. <strong>Switch</strong> data window entries<br />
Entry<br />
Description<br />
Summary Group<br />
<strong>Switch</strong> Type<br />
First Port Address<br />
World Wide Name<br />
Serial Number<br />
Reason for Status<br />
Vendor<br />
MAC Address<br />
<strong>Switch</strong> UUID<br />
CPLD Revision<br />
Negotiated Domain ID<br />
Configured Domain ID<br />
Domain ID Lock<br />
Number of Ports<br />
Operational State<br />
Administrative State<br />
Configured Admin State<br />
Beacon Status<br />
<strong>Switch</strong> model<br />
<strong>Switch</strong> Fibre Channel address<br />
<strong>Switch</strong> world wide name<br />
Number assigned to each chassis<br />
The reason for the operational state.<br />
<strong>Switch</strong> manufacturer<br />
Media Access Control address<br />
The switch's universally unique ID<br />
Complex Programmable Logic Device revision<br />
The domain ID currently being used by the fabric<br />
The domain ID defined by network administrator<br />
Domain ID lock status. Prevents (True) or permits (False)<br />
dynamic domain ID reassignment<br />
Number of ports activated on the switch<br />
<strong>Switch</strong> operational state: Online, Offline, Diagnostic, Down<br />
Current switch administrative state<br />
<strong>Switch</strong> administrative state that is stored in the switch configuration<br />
Beacon status. <strong>Switch</strong> LEDs are blinking (On) or not (off).<br />
Status Group<br />
Operational State<br />
Administrative State<br />
Configured Admin State<br />
Beacon Status<br />
Reason for Status<br />
Temperature<br />
Fan 1 Status<br />
Fan 2 Status<br />
Fan 3 Status<br />
Power Supply 1 Status<br />
<strong>Switch</strong> operational state: Online, Offline, Diagnostic, Down<br />
Current switch administrative state<br />
<strong>Switch</strong> administrative state that is stored in the switch configuration<br />
Beacon status. <strong>Switch</strong> LEDs are blinking (On) or not (off).<br />
The reason for the operational state<br />
Internal switch temperature in degrees Celsius<br />
NA—does not apply to this switch<br />
NA—does not apply to this switch<br />
NA—does not apply to this switch<br />
NA—does not apply to this switch<br />
<strong>Chapter</strong> 4. Managing switches 43