Severity is indicated in the severity column using icons as described in Table 4.<br />
Table 4. Severity levels<br />
Severity Icon<br />
Description<br />
Alarm—an alarm is a serviceable event. This alarm means that attention<br />
by the user or field service is required. Alarms are posted asynchronously<br />
to the screen and cannot be turned off. If the alarm denotes that a<br />
system error has occurred, the customer and/or field representative will<br />
generally be directed to provide a "show support" capture of the switch.<br />
Critical event—an event that indicates a potential failure. Critical log<br />
messages are events that warrant notice by the user. By default, these log<br />
messages will be posted to the screen. Critical log messages do not have<br />
alarm status as they require no immediate attention from a user or service<br />
representative.<br />
Warning event—an event that indicates errors or other conditions that<br />
may require attention to maintain maximum performance. Warning messages<br />
will not be posted to the screen unless the log is configured to do<br />
so. Warning messages are not disruptive and, therefore, do not meet the<br />
criteria of Critical. The user need not be informed asynchronously.<br />
No icon<br />
Informative—an unclassified event that provides supporting information.<br />
Notes:<br />
• Events (Alarms, Critical, Warning, and Informative) generated by the web<br />
applet are not saved on the switch. They are permanently discarded when<br />
you close a QuickTools session, but you can save these events to a file on the<br />
workstation before you close QuickTools and read it later with a text editor or<br />
browser.<br />
• Events generated by the switch are stored on the switch, and will be retrieved<br />
when the web applet is restarted. Some alarms are configurable.<br />
<strong>Chapter</strong> 3. Managing fabrics 17