TROUBLESHOOTING AND MAINTENANCE A<br />

Step 3. At rotating gobo wheel, rotate until required gobo/filter is accessible.<br />

Step 4. FOR GAGS OR GOBOS THAT DO NOT REQUIRE A CARRIER - Locate end of coiled<br />

spring which is fitted under carrier tab. Using hook and pick tool or small slotted<br />

screwdriver, push end of spring from under tab until it is free. Once free, remove entire<br />

coiled spring.<br />

Step 5. FOR GOBOS THAT ARE FITTED INTO THEIR OWN CARRIER - Remove gobo by<br />

pressing on side opposite of "O" Ring.<br />

Only For Gags or Gobos that do not require a carrier<br />

Spring<br />

Gobo<br />

Carrier<br />

Flat side<br />

Orient flat side to<br />

flat side of carrier<br />

Flat Locator<br />

Markers<br />

Free end of spring<br />

and then remove<br />

Figure A-9: Rotating Gobo Removal<br />

CAUTION: Do not touch gobos with bare fingers. Wear cotton gloves or other covering while<br />

replacing. Clean with glass cleaner and soft cloth if required.<br />

Step 6. Remove gobo.<br />

Step 7. Aligning flat side correctly and orienting “black” side of gobo toward front lens, install new<br />

gobo.<br />

Step 8. Re-install spring, ensuring it is fully secured under carrier tabs (for Gags or Gobos that do<br />

not require a carrier).<br />

Step 9. Re-install removable cover.<br />