TROUBLESHOOTING AND MAINTENANCE A<br />

CAUTION: Wear cotton gloves or other covering while servicing lamp. Touching lamp glass with<br />

bare fingers will leave oil and may cause the lamp to explode or reduce lamp life. If required, use<br />

alcohol and cotton cloth to thoroughly clean glass portion of lamp.<br />

Step 4. Remove lamp by pulling straight out of socket.<br />

Step 5. Install new lamp by pressing into socket. Ensure lamp is fully seated in socket and parallel<br />

to guide rods. (Lamp can be damaged when inserted through reflector if not parallel to<br />

guide rods.)<br />

Step 6. Align guide rods in guide holes and slide backcap into head assembly. Re-tighten captive<br />

knob.<br />

Step 7. If required, reset lamp hour counter as follows. (Refer to “Menu System” chapter on page 49<br />

for more information.)<br />

a. Power up luminaire.<br />

b. At Menu Display, press [Menu].<br />

c. Press [Up] / [Down] arrows until Config (Configuration) appears. Press [Enter].<br />

d. Press [Up] / [Down] arrows until LAMP appears. Press [Enter].<br />

e. Press [Up] / [Down] arrows to access ResetHrs (Reset Lamp Hours). Press [Enter] to<br />

reset lamp hour counter.<br />

Step 8. Align lamp. Refer to “Align Lamp for Flat Field” on page 19.<br />

02.9676.0019 A 05-January-2004 67