TROUBLESHOOTING AND MAINTENANCE A<br />
CAUTION: Wear cotton gloves or other covering while servicing lamp. Touching lamp glass with<br />
bare fingers will leave oil and may cause the lamp to explode or reduce lamp life. If required, use<br />
alcohol and cotton cloth to thoroughly clean glass portion of lamp.<br />
Step 4. Remove lamp by pulling straight out of socket.<br />
Step 5. Install new lamp by pressing into socket. Ensure lamp is fully seated in socket and parallel<br />
to guide rods. (Lamp can be damaged when inserted through reflector if not parallel to<br />
guide rods.)<br />
Step 6. Align guide rods in guide holes and slide backcap into head assembly. Re-tighten captive<br />
knob.<br />
Step 7. If required, reset lamp hour counter as follows. (Refer to “Menu System” chapter on page 49<br />
for more information.)<br />
a. Power up luminaire.<br />
b. At Menu Display, press [Menu].<br />
c. Press [Up] / [Down] arrows until Config (Configuration) appears. Press [Enter].<br />
d. Press [Up] / [Down] arrows until LAMP appears. Press [Enter].<br />
e. Press [Up] / [Down] arrows to access ResetHrs (Reset Lamp Hours). Press [Enter] to<br />
reset lamp hour counter.<br />
Step 8. Align lamp. Refer to “Align Lamp for Flat Field” on page 19.<br />
02.9676.0019 A 05-January-2004 67