Verify software version at luminaire:<br />

Step 1. At Menu Display, press [Menu].<br />

Step 2. Press [Up] / [Down] arrows until Fixture appears. Press [Enter].<br />

Step 3. Press [Up] / [Down] arrows until Version appears. Press [Enter].<br />

OPERATION : UPDATING SOFTWARE 3<br />

The first half of the version date will be displayed as MM/DD/YY (month/day/year): For<br />

example, 07/21/02 = July 21, 2002<br />

Press [Enter] to display second half of version date.<br />

The second half of the version date will be displayed as XX.XX (For example, 16.36 =<br />

4:36 pm).<br />

Transferring Software From Luminaire to Luminaire<br />

It is possible to transfer specific software versions between luminaires. As in the case of installing new<br />

software versions, multiple luminaires can be programmed at the same time if they are data linked<br />

together (refer to “Connecting Data and Power” on page 17), however a maximum of 32 luminaires<br />

can be updated at once.<br />

Hardware Requirements<br />

Data cables used in this process must have two twisted pairs and a shield. It is also recommended that<br />

cables meet all other USITT DMX specification requirements. Refer to “Data Cables” on page 10.<br />

A DMX termination connector is used in this process. Refer to page 12 for more information regarding<br />

the construction of this connector.<br />

Master luminaire containing<br />

software version to download<br />

~ AC IN<br />

AC PWR<br />

DATA IN DATA THRU<br />

MENU ENTER<br />

~ AC IN<br />

Luminaire 1<br />

requiring update<br />

AC PWR<br />

DATA IN DATA THRU<br />

Figure 3-9: Software Transfer Setup<br />

Transfer Procedure<br />

This procedure is used to transfer software versions between luminaires.<br />

Step 1. At last luminaire, install DMX termination connector into DATA THRU XLR connector.<br />

Step 2. At master luminaire (first in chain) Menu Display, press [Menu].<br />

Step 3. Press [Up] / [Down] arrows until Fixture appears.<br />

02.9676.0019 A 05-January-2004 47<br />

MENU ENTER<br />

Data Thru Data Thru<br />

~ AC IN<br />

Luminaire 2<br />

requiring update<br />

AC PWR<br />

DATA IN DATA THRU<br />

MENU ENTER<br />

DMX Termination Connector