30.12.2014 Views

slide guide

slide guide

slide guide

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SLIDE GUIDE<br />

GREASE FITTING<br />

HIGH LOAD CAPACITY AND LONG LIFE<br />

A grease fitting is attached to the return cap of SGL type and GL type <strong>guide</strong> blocks for lubrication purposes.<br />

Unless otherwise specified, the orientation of the grease fitting is as shown in Figure A-57. When more than<br />

2 blocks are used on one rail, please specify the grease fitting orientation.<br />

Figure A-57 Grease Fitting Orientation<br />

The GL type <strong>slide</strong> <strong>guide</strong> has a load rating of 1.2 to 1.6 times greater than the load rating of other branded<br />

"low-noise" type <strong>guide</strong>s. This high load capacity enables a longer travel life.<br />

Figure A-59 Load Rating Comparison<br />

reference surface side<br />

<br />

<br />

GL25TF<br />

SLIDE GUIDE<br />

NB mark side<br />

reference surface side<br />

10 15<br />

20 25<br />

basic dynamic load rating C(kN)<br />

NOTE: Except for GL-H types.<br />

CLEAN OPERATIOIN<br />

NB mark side<br />

Ball cushions eliminate metal contact between the steel balls and prevent excess grease spatter, enabling<br />

linear operation with low levels of dust generation.<br />

Figure A-60 Dust Generation Data<br />

1000<br />

LOW NOISE<br />

Ball cushions are inserted between the steel balls preventing metal contact, enabling low noise.<br />

Figure A-58 Noise Data<br />

noise leveldB(A)<br />

70<br />

40<br />

600<br />

quiet <strong>guide</strong> series GL30TF<br />

conventional standard series SGL30TF<br />

800<br />

test conditions/noise meter position: 710 mm above 45 diagonal<br />

lubricant: grease<br />

preload: standard<br />

speed(mm/s)<br />

1,000<br />

1,200<br />

number of generated dust particles<br />

(minimum particle diameter 0.3 μm/1 CF)<br />

100<br />

10<br />

GL20TF+GU<br />

SGL20TF+GU<br />

SGL20TF+lithium-based grease<br />

test conditions/speed: 700mm/s<br />

stroke: 200mm<br />

airflow rate: 3m 3 /min<br />

1<br />

10 20 30 40 50 60 70 80 90 100<br />

NOTE: Clean room level is to be specified when ordering.<br />

time(hours)<br />

A-46 A-47