44 Crocus SHDSL G703 Chapter 4 User manual Maintaining the Crocus SHDSL G703 4.1.2 Starting a TMA session through the control connector To establish a connection between the computer running TMA and the Crocus SHDSL G703 through the control connector, proceed as follows: Step Action 1 Connect a serial port of your computer (e.g. COM1) through a straight DB9 male - female cable with the control connector of the Crocus modem. 2 Start TMA. 3 In the TMA window, either … • select from the menu bar: Connect → Device… • or press the shortcut key: Ctrl+N • or press on the Connect to device button: The Connect (to a device) window is being displayed as in the following figure: 4 In the Connect (to a device) window, configure the following parameters: • Select the option Serial, and specify the COM port of your computer the Crocus SHDSL G703 is connected to. • If a password has previously been configured in the Crocus SHDSL G703 then also fill in the password field. 5 If the necessary parameters are filled in, press the Next > button.

Crocus SHDSL G703 Chapter 4 45 User manual Maintaining the Crocus SHDSL G703 Step Action 6 In the TMA window, either … • select from the menu bar: Connect → Select device… • or press the shortcut key: Ctrl+D • or press on the Select device button: The Connect (select a device) window is being displayed as in the following figure: 7 In order to connect to … • the local Crocus SHDSL G703, choose On device. • the remote Crocus SHDSL G703, choose After device and enter relative NMS address 1 or higher. If a password has previously been configured in the Crocus SHDSL G703 then also fill in the password field. 8 If the necessary parameters are filled in, press the Finish button. 9 After a couple of seconds, the attributes of the selected Crocus SHDSL G703 appear in the TMA window.

44 <strong>Crocus</strong> <strong>SHDSL</strong> G703 Chapter 4<br />

User manual<br />

Maintaining the <strong>Crocus</strong> <strong>SHDSL</strong> G703<br />

4.1.2 Starting a TMA session through the control connector<br />

To establish a connection between the computer running TMA and the <strong>Crocus</strong> <strong>SHDSL</strong> G703 through<br />

the control connector, proceed as follows:<br />

Step<br />

Action<br />

1 Connect a serial port of your computer<br />

(e.g. COM1) through a<br />

straight DB9 male - female cable<br />

with the control connector of the<br />

<strong>Crocus</strong> modem.<br />

2 Start TMA.<br />

3 In the TMA window, either …<br />

• select from the menu bar: Connect → Device…<br />

• or press the shortcut key: Ctrl+N<br />

• or press on the Connect to device button:<br />

The Connect (to a device) window is being displayed as<br />

in the following figure:<br />

4 In the Connect (to a device) window, configure the following parameters:<br />

• Select the option Serial, and specify the COM port of your computer the <strong>Crocus</strong><br />

<strong>SHDSL</strong> G703 is connected to.<br />

• If a password has previously been configured in the <strong>Crocus</strong> <strong>SHDSL</strong> G703 then also<br />

fill in the password field.<br />

5 If the necessary parameters are filled in, press the Next > button.