252 <strong>Crocus</strong> <strong>SHDSL</strong> G703 Chapter 12<br />

User manual<br />

Diagnostic tests<br />

12.2.4 Remote digital loop<br />

Initiating the RDL test establishes a digital loop on the remote <strong>Crocus</strong> <strong>SHDSL</strong> G703. This loop is compliant<br />

to loop 2 as described in the ITU-T recommendation V.54.<br />

The loop is situated immediately behind the digital part of the remote <strong>Crocus</strong> <strong>SHDSL</strong> G703, schematically<br />

represented as follows:<br />

Make sure that on the remote <strong>Crocus</strong> <strong>SHDSL</strong> G703 the rdlDetect attribute is set to enabled (refer to 6.6 -<br />

DTE Interface configuration attributes on page 148). Else it is not possible to initiate an RDL test on the<br />

remote.<br />

How to use this test<br />

Example:<br />

Phase<br />

Description<br />

1 Start an RDL-ET test on the local <strong>Crocus</strong> <strong>SHDSL</strong> G703.<br />

⇒A digital loop is established on the remote <strong>Crocus</strong> <strong>SHDSL</strong> G703 and a test pattern<br />

is sent down the line.<br />

2 Because the remote side is in a digital loop, the test pattern returns to the local <strong>Crocus</strong><br />

<strong>SHDSL</strong> G703.<br />

3 The detector receives this test pattern, and can compare it with the original transmitted<br />

pattern.<br />

⇒The quantity of inconsistencies that might exist between the original and the<br />

returned pattern could be an indication of the line quality.