<strong>Crocus</strong> <strong>SHDSL</strong> G703 Chapter 11 243<br />

User manual<br />

Software download<br />

11.5 Downloading in loader mode<br />

When a download of application software has failed or when a flash memory error occurs, the <strong>Crocus</strong><br />

<strong>SHDSL</strong> G703 normally remains in loader mode. In other words, you can immediately retry to download<br />

the application software again.<br />

However, it may be possible that the application software becomes corrupt making the <strong>Crocus</strong> <strong>SHDSL</strong><br />

G703 inoperative and inaccessible to TMA. In that case, new application software can still be downloaded<br />

by forcing the <strong>Crocus</strong> <strong>SHDSL</strong> G703 in loader mode using a DIP switch (refer to 3.1.2 - DIP<br />

switches of the TT on page 36.<br />

To download application software to a <strong>Crocus</strong> <strong>SHDSL</strong> G703 in loader mode, proceed as follows:<br />

Step<br />

Action<br />

1 Disconnect the <strong>Crocus</strong> <strong>SHDSL</strong> G703 from the power supply.<br />

2 Set DIP switch bank DS1 position 2 to off.<br />

To locate this DIP switch bank and for the DIP switch setting procedure, refer to 3 - DIP<br />

switches and straps of the <strong>Crocus</strong> <strong>SHDSL</strong> G703 on page 33.<br />

3 Reconnect the power supply to the <strong>Crocus</strong> <strong>SHDSL</strong> G703.<br />

⇒The <strong>Crocus</strong> <strong>SHDSL</strong> G703 is now in loader mode.<br />

4 Now proceed as explained in 11.4 - Downloading with TML on page 242.<br />

5 When the download is finished, disconnect the <strong>Crocus</strong> <strong>SHDSL</strong> G703 from the power supply<br />

again.<br />

6 Reset DIP switch bank DS1 position 2 to on.<br />

7 Reconnect the power supply to the <strong>Crocus</strong> <strong>SHDSL</strong> G703.