240 Crocus SHDSL G703 Chapter 11 User manual Software download 11.2 Important download issues • When you upgrade the application software of the Crocus SHDSL G703, do not power off the Crocus SHDSL G703 until the TST LED stops blinking. Else the application software upgrade will fail. • When you upgrade the application software of the Crocus SHDSL G703, do not power off the Crocus SHDSL G703 as long as only the PWR LED blinks and all the other LEDs are off. Else the application software upgrade will fail. • When a Crocus SHDSL G703 is managed by a management concentrator (i.e. it is present in the management concentrator its objectTable and being polled), it is no longer possible to download software through the Crocus SHDSL G703 its control connector using TMA or TML. Instead, use the software distribution feature of the management concentrator. • It is not possible to use the software distribution feature of a management concentrator to download loader software to a Crocus SHDSL G703. • When you download new loader software, you also have to download the application software again.

Crocus SHDSL G703 Chapter 11 241 User manual Software download 11.3 Downloading with TMA To download application software with TMA, proceed as follows: Step Action 1 Establish a link between TMA and the Crocus SHDSL G703 through the control connector. Refer to 4.1 - Starting TMA on the Crocus SHDSL G703 on page 42. 2 In the TMA window select Tools → Download… 3 In the TMA - Download window, select the Options tab:· • Set the initial transfer speed to 9600 bps.· • If you set the maximum transfer speed to 115200 bps, the actual transfer speed will be negotiated between the computer and the Crocus SHDSL G703 and will be between 9600 bps and 115200 bps. 4 In the TMA - Download window, select the Configuration tab, and press Add… 5 In the Remote filename window: 1. Select the filename you want to download (Txxxxxxx.00). 2. Type CONTROL in the Remote file field. 3. Press Open. 6 When the TMA - Download window reappears, press OK. ⇒The Crocus SHDSL G703 falls back to loader mode, then a DOS window opens and shows the download progress.

<strong>Crocus</strong> <strong>SHDSL</strong> G703 Chapter 11 241<br />

User manual<br />

Software download<br />

11.3 Downloading with TMA<br />

To download application software with TMA, proceed as follows:<br />

Step<br />

Action<br />

1 Establish a link between TMA and the <strong>Crocus</strong> <strong>SHDSL</strong> G703 through the control connector.<br />

Refer to 4.1 - Starting TMA on the <strong>Crocus</strong> <strong>SHDSL</strong> G703 on page 42.<br />

2 In the TMA window select Tools → Download…<br />

3 In the TMA - Download window, select the Options tab:·<br />

• Set the initial transfer speed to 9600 bps.·<br />

• If you set the maximum transfer speed to 115200 bps, the actual transfer speed will<br />

be negotiated between the computer and the <strong>Crocus</strong> <strong>SHDSL</strong> G703 and will be<br />

between 9600 bps and 115200 bps.<br />

4 In the TMA - Download window, select the Configuration tab, and press Add…<br />

5 In the Remote filename window:<br />

1. Select the filename you want to download (Txxxxxxx.00).<br />

2. Type CONTROL in the Remote file field.<br />

3. Press Open.<br />

6 When the TMA - Download window reappears, press OK.<br />

⇒The <strong>Crocus</strong> <strong>SHDSL</strong> G703 falls back to loader mode, then a DOS window opens<br />

and shows the download progress.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!