222 Crocus SHDSL G703 Chapter 9 Reference manual Alarm attributes crocusShdslTtRpG703/line/alarmInfo The different alarms related to the line object together with their explanation and their default alarmMask and alarmLevel value are given in the following table: The alarm … is generated … Default value alarmMask alarmLevel linkDown invalidNumRepeaters when no data link towards the remote Crocus SHDSL G703 is present.It does not necessarily mean that the line pair is disconnected. If the line quality is so bad that data transfer is not possible, a linkDown alarm is generated. when the number of repeaters you entered in the line/numExpectedRepeaters configuration attribute does not match the actual number of repeaters discovered by the Crocus SHDSL G703.The actual number of repeaters discovered by the Crocus SHDSL G703 can be seen in the line/num- DiscoveredRepeaters status attribute. enabled 3 disabled 1 testActive when a test is active. disabled 1

Crocus SHDSL G703 Chapter 9 223 Reference manual Alarm attributes 9.5 Line pair alarms This section describes the following alarm attributes: • crocusShdslTtRpG703/line/linePair[ ]/alarmInfo on page 224 In case of a Crocus SHDSL G703 2P, two linePair objects are present: linePair [1] and linePair [2]. Refer to 9.2 - Introducing the alarm attributes on page 210 for the general alarm attributes.

222 <strong>Crocus</strong> <strong>SHDSL</strong> G703 Chapter 9<br />

Reference manual<br />

Alarm attributes<br />

crocusShdslTtRpG703/line/alarmInfo<br />

The different alarms related to the line object together with their explanation and their default alarmMask<br />

and alarmLevel value are given in the following table:<br />

The alarm … is generated … Default value<br />

alarmMask<br />

alarmLevel<br />

linkDown<br />

invalidNumRepeaters<br />

when no data link towards the remote <strong>Crocus</strong><br />

<strong>SHDSL</strong> G703 is present.It does not<br />

necessarily mean that the line pair is disconnected.<br />

If the line quality is so bad that<br />

data transfer is not possible, a linkDown<br />

alarm is generated.<br />

when the number of repeaters you entered<br />

in the line/numExpectedRepeaters configuration<br />

attribute does not match the actual number<br />

of repeaters discovered by the <strong>Crocus</strong><br />

<strong>SHDSL</strong> G703.The actual number of<br />

repeaters discovered by the <strong>Crocus</strong><br />

<strong>SHDSL</strong> G703 can be seen in the line/num-<br />

DiscoveredRepeaters status attribute.<br />

enabled 3<br />

disabled 1<br />

testActive when a test is active. disabled 1