220 <strong>Crocus</strong> <strong>SHDSL</strong> G703 Chapter 9<br />

Reference manual<br />

Alarm attributes<br />

The alarm … is generated … Default value<br />

alarmMask<br />

alarmLevel<br />

localPowerFail<br />

codeConsistencyFail<br />

configConsistencyFail<br />

when the local power of the <strong>Crocus</strong> <strong>SHDSL</strong><br />

G703 fails<br />

when the software consistency imposed by<br />

the management concentrator on the <strong>Crocus</strong><br />

<strong>SHDSL</strong> G703 fails. For example,<br />

because of a loss of contact.<br />

On the management concentrator, check<br />

the status attribute nmsgroup/softConsistencyStatus<br />

to determine the problem.<br />

when the configuration consistency<br />

imposed by the management concentrator<br />

on the <strong>Crocus</strong> <strong>SHDSL</strong> G703 fails. For<br />

example, because of a loss of contact.On<br />

the management concentrator, check the<br />

status attributes nmsgroup/objectTable/config-<br />

State and configDiag to determine the problem.<br />

disabled 3<br />

disabled 1<br />

disabled 1<br />

crocusShdslTtRpG703/Cold Boot<br />

This action will reboot the <strong>Crocus</strong> <strong>SHDSL</strong> G703 while the power stays up (the <strong>Crocus</strong> <strong>SHDSL</strong> G703 also<br />

reboots if it is powered down and up again).