Crocus SHDSL G703.pdf - FTP Directory Listing

Crocus SHDSL G703.pdf - FTP Directory Listing Crocus SHDSL G703.pdf - FTP Directory Listing

oneaccess.net.com
from oneaccess.net.com More from this publisher
30.12.2014 Views

206 Crocus SHDSL G703 Chapter 8 Reference manual Performance attributes crocusShdslTtRpG703/operatingSystem/usedProcPower This table lists the used processing power for the 11 most recent 30 seconds intervals. The processing power is expressed as a percentage of the total processing power. Each entry in the attribute used- ProcPower is composed of the following attributes: Value sysUpTime minimumPP (%) averagePP (%) maximumPP (%) Description Displays the elapsed time since the last cold boot. The next values are for the 30 seconds period before this relative time stamp. This is the minimum percentage of processing power in use during the last 30 seconds. This is the average percentage of processing power in use during the last 30 seconds. This is the maximum percentage of processing power in use during the last 30 seconds. crocusShdslTtRpG703/operatingSystem/taskInfo This attribute contains status information concerning the different tasks running on the processor. It is a table grouping up to 31 task slots, which is the maximum number of parallel tasks running on the processor's operating system. This attribute contains the same information as taskInfo in the status group (refer to 7.7 - Operating system status attributes on page 184).

Crocus SHDSL G703 Chapter 9 207 Reference manual Alarm attributes 9 Alarm attributes This chapter discusses the alarm attributes of the Crocus SHDSL G703. The following gives an overview of this chapter. • 9.1 - Alarm attribute overview on page 208 • 9.2 - Introducing the alarm attributes on page 210 • 9.3 - General alarms on page 218 • 9.4 - Line alarms on page 221 • 9.5 - Line pair alarms on page 223 • 9.6 - Repeater and end alarms on page 226 • 9.7 - Interface alarms on page 229

<strong>Crocus</strong> <strong>SHDSL</strong> G703 Chapter 9 207<br />

Reference manual<br />

Alarm attributes<br />

9 Alarm attributes<br />

This chapter discusses the alarm attributes of the <strong>Crocus</strong> <strong>SHDSL</strong> G703. The following gives an overview<br />

of this chapter.<br />

• 9.1 - Alarm attribute overview on page 208<br />

• 9.2 - Introducing the alarm attributes on page 210<br />

• 9.3 - General alarms on page 218<br />

• 9.4 - Line alarms on page 221<br />

• 9.5 - Line pair alarms on page 223<br />

• 9.6 - Repeater and end alarms on page 226<br />

• 9.7 - Interface alarms on page 229

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!