200 Crocus SHDSL G703 Chapter 8 Reference manual Performance attributes 8.6 G703 interface performance attributes This section describes the following performance attributes: • crocusShdslTtRpG703/g703/G703Performance on page 201 • crocusShdslTtRpG703/g703/g703Performance on page 201 • crocusShdslTtRpG703/g703/G826Performance on page 202 • crocusShdslTtRpG703/g703/g826Performance on page 202 This section describes the following actions: • crocusShdslTtRpG703/g703/testActivation on page 202
Crocus SHDSL G703 Chapter 8 201 Reference manual Performance attributes crocusShdslTtRpG703/g703/G703Performance This structured value displays the 2 hours, 24 hours and 7 days performance summary of the G703 interface. The G703Performance structured value elements are the following: Element sysUpTime losCount losTime aisCount aisTime lfaCount lfaTime For the corresponding period, this value displays … the elapsed time since the last cold boot. the number of times a Loss Of Signal condition occurred. the amount of time a Loss Of Signal condition was active. the number of times an Alarm Indication Signal condition occurred. the amount of time an Alarm Indication Signal condition was active. the number of times a Loss of Frame Alignment condition occurred. This is only relevant when working in framed mode. the amount of time a Loss of Frame Alignment condition was active. This is only relevant when working in framed mode. Also see G703 interface performance definitions. crocusShdslTtRpG703/g703/g703Performance This structured value displays the performance summary of the G703 interface since the last cold boot. Except for sysUpTime, the structured value elements are the same as for the G703Performance attribute.
- Page 161 and 162: Crocus SHDSL G703 Chapter 6 149 Ref
- Page 163 and 164: Crocus SHDSL G703 Chapter 6 151 Ref
- Page 165 and 166: Crocus SHDSL G703 Chapter 6 153 Ref
- Page 167 and 168: Crocus SHDSL G703 Chapter 7 155 Ref
- Page 169 and 170: Crocus SHDSL G703 Chapter 7 157 Ref
- Page 171 and 172: Crocus SHDSL G703 Chapter 7 159 Ref
- Page 173 and 174: Crocus SHDSL G703 Chapter 7 161 Ref
- Page 175 and 176: Crocus SHDSL G703 Chapter 7 163 Ref
- Page 177 and 178: Crocus SHDSL G703 Chapter 7 165 Ref
- Page 179 and 180: Crocus SHDSL G703 Chapter 7 167 Ref
- Page 181 and 182: Crocus SHDSL G703 Chapter 7 169 Ref
- Page 183 and 184: Crocus SHDSL G703 Chapter 7 171 Ref
- Page 185 and 186: Crocus SHDSL G703 Chapter 7 173 Ref
- Page 187 and 188: Crocus SHDSL G703 Chapter 7 175 Ref
- Page 189 and 190: Crocus SHDSL G703 Chapter 7 177 Ref
- Page 191 and 192: Crocus SHDSL G703 Chapter 7 179 Ref
- Page 193 and 194: Crocus SHDSL G703 Chapter 7 181 Ref
- Page 195 and 196: Crocus SHDSL G703 Chapter 7 183 Ref
- Page 197 and 198: Crocus SHDSL G703 Chapter 7 185 Ref
- Page 199 and 200: Crocus SHDSL G703 Chapter 8 187 Ref
- Page 201 and 202: Crocus SHDSL G703 Chapter 8 189 Ref
- Page 203 and 204: Crocus SHDSL G703 Chapter 8 191 Ref
- Page 205 and 206: Crocus SHDSL G703 Chapter 8 193 Ref
- Page 207 and 208: Crocus SHDSL G703 Chapter 8 195 Ref
- Page 209 and 210: Crocus SHDSL G703 Chapter 8 197 Ref
- Page 211: Crocus SHDSL G703 Chapter 8 199 Ref
- Page 215 and 216: Crocus SHDSL G703 Chapter 8 203 Ref
- Page 217 and 218: Crocus SHDSL G703 Chapter 8 205 Ref
- Page 219 and 220: Crocus SHDSL G703 Chapter 9 207 Ref
- Page 221 and 222: Crocus SHDSL G703 Chapter 9 209 Ref
- Page 223 and 224: Crocus SHDSL G703 Chapter 9 211 Ref
- Page 225 and 226: Crocus SHDSL G703 Chapter 9 213 Ref
- Page 227 and 228: Crocus SHDSL G703 Chapter 9 215 Ref
- Page 229 and 230: Crocus SHDSL G703 Chapter 9 217 Ref
- Page 231 and 232: Crocus SHDSL G703 Chapter 9 219 Ref
- Page 233 and 234: Crocus SHDSL G703 Chapter 9 221 Ref
- Page 235 and 236: Crocus SHDSL G703 Chapter 9 223 Ref
- Page 237 and 238: Crocus SHDSL G703 Chapter 9 225 Ref
- Page 239 and 240: Crocus SHDSL G703 Chapter 9 227 Ref
- Page 241 and 242: Crocus SHDSL G703 Chapter 9 229 Ref
- Page 243 and 244: Crocus SHDSL G703 Chapter 10 231 Us
- Page 245 and 246: Crocus SHDSL G703 Chapter 10 233 Us
- Page 247 and 248: Crocus SHDSL G703 Chapter 11 235 Us
- Page 249 and 250: Crocus SHDSL G703 Chapter 11 237 Us
- Page 251 and 252: Crocus SHDSL G703 Chapter 11 239 Us
- Page 253 and 254: Crocus SHDSL G703 Chapter 11 241 Us
- Page 255 and 256: Crocus SHDSL G703 Chapter 11 243 Us
- Page 257 and 258: Crocus SHDSL G703 Chapter 12 245 Us
- Page 259 and 260: Crocus SHDSL G703 Chapter 12 247 Us
- Page 261 and 262: Crocus SHDSL G703 Chapter 12 249 Us
<strong>Crocus</strong> <strong>SHDSL</strong> G703 Chapter 8 201<br />
Reference manual<br />
Performance attributes<br />
crocusShdslTtRpG703/g703/G703Performance<br />
This structured value displays the 2 hours, 24 hours and 7 days performance summary of the G703 interface.<br />
The G703Performance structured value elements are the following:<br />
Element<br />
sysUpTime<br />
losCount<br />
losTime<br />
aisCount<br />
aisTime<br />
lfaCount<br />
lfaTime<br />
For the corresponding period, this value displays …<br />
the elapsed time since the last cold boot.<br />
the number of times a Loss Of Signal condition occurred.<br />
the amount of time a Loss Of Signal condition was active.<br />
the number of times an Alarm Indication Signal condition occurred.<br />
the amount of time an Alarm Indication Signal condition was active.<br />
the number of times a Loss of Frame Alignment condition occurred. This is only<br />
relevant when working in framed mode.<br />
the amount of time a Loss of Frame Alignment condition was active. This is only<br />
relevant when working in framed mode.<br />
Also see G703 interface performance definitions.<br />
crocusShdslTtRpG703/g703/g703Performance<br />
This structured value displays the performance summary of the G703 interface since the last cold boot.<br />
Except for sysUpTime, the structured value elements are the same as for the G703Performance<br />
attribute.