178 <strong>Crocus</strong> <strong>SHDSL</strong> G703 Chapter 7<br />

Reference manual<br />

Status attributes<br />

crocusShdslTtRpG703/end/eocAlarmThresholds<br />

This attribute is only retrieved in case the eocHandling attribute is set to info or alarmConfiguration.<br />

What this attribute displays depends on the setting of the line/eocHandling attribute:<br />

If eocHandling<br />

is set to …<br />

info<br />

alarmConfiguration<br />

then …<br />

the eocAlarmThresholds attribute displays the values as set in the line/linkAlarmThresholds<br />

attribute on the remote 1 device or repeater.<br />

the eocAlarmThresholds attribute displays the values as set in the line/linkAlarmThresholds<br />

attribute on the central 2 device.<br />

Remark<br />

Note that the values are rounded off. E.g. when 28.6 dB is configured on the central<br />

modem, then 28 dB is shown on the remote device or repeater.<br />

1. The remote device is the device on which the channel attribute is set to remote.<br />

2. The central device is the device on which the channel attribute is set to central.<br />

The eocAlarmThresholds structure contains the following elements:<br />

• lineAttenuation<br />

• signalNoise