<strong>Crocus</strong> <strong>SHDSL</strong> G703 Chapter 6 141<br />

Reference manual<br />

Configuration attributes<br />

Element<br />

errSecRatio-<br />

Exceeded<br />

sevErrSecRatio-<br />

Exceeded<br />

bBErrRatio-<br />

Exceeded<br />

Description<br />

Use this element to set the alarm threshold value of the errored seconds ratio. The<br />

errored seconds ratio is the ratio of errored seconds to total seconds during a 15<br />

minute time interval. So if the errored seconds ratio …<br />

• exceeds this value within a 15 minute period 3 , then the errSecRatioExceeded<br />

alarm is raised.<br />

• drops below this value within a 15 minute period, then the errSecRatioExceeded<br />

alarm is cleared.<br />

Use this element to set the alarm threshold value of the severely errored seconds<br />

ratio. The severely errored seconds ratio is the ratio of severely errored seconds<br />

to total seconds during a 15 minute interval. So if the severely errored seconds<br />

ratio …<br />

• exceeds this value within a 15 minute period 3 , then the sevErrSecRatioExceeded<br />

alarm is raised.<br />

• drops below this value within a 15 minute period, then the sevErrSecRatioExceeded<br />

alarm is cleared.<br />

Use this element to set the alarm threshold value of the background block error<br />

ratio. The background block error ratio is the ratio of background block errors to<br />

total blocks during a 15 minute time interval. The count of total blocks excludes all<br />

blocks during severely errored seconds. So if the background block error ratio …<br />

• exceeds this value within a 15 minute period 3 , then the bBErrRatioExceeded alarm<br />

is raised.<br />

• drops below this value within a 15 minute period, then the bBErrRatioExceeded<br />

alarm is cleared.<br />

1. The central device is the device on which the channel attribute is set to central.<br />

2. The remote device is the device on which the channel attribute is set to remote.<br />

3. The 15 minute periods run synchronous with the 2 hour periods of the line/h2Line performance<br />

attribute. Because alarms are raised or cleared within 15 minute periods, there is a delay in the<br />

alarm status. For example, suppose that in the first minute of a 15 minute period the errSecRatioExceeded<br />

value is exceeded, then the errSecRatioExceeded alarm is raised when the full 15<br />

minute period has passed. The alarm is only cleared if in the next 15 minute period the errSecRatioExceeded<br />

value is not exceeded.