<strong>Crocus</strong> <strong>SHDSL</strong> G703 Chapter 6 139<br />

Reference manual<br />

Configuration attributes<br />

crocusShdslTtRpG703/line/eocChannel<br />

Default:itu-G.991.2<br />

Range: proprietary / itu-<br />

Use the eocChannel attribute to determine how the checksum of Embedded<br />

G.991.2<br />

Operations Channel (EOC) messages is calculated. Make sure that on both<br />

the central and the remote device the eocChannel attribute is set to the same value.<br />

The eocChannel attribute has the following values:<br />

Value<br />

proprietary<br />

itu-G.991.2<br />

Description<br />

The checksum is calculated using a proprietary method.<br />

The checksum is calculated using the G.<strong>SHDSL</strong> standard method.<br />

crocusShdslTtRpG703/line/txEocMessages<br />

Default:bothPairs<br />

Range: pair1 / bothPairs<br />

This attribute is only present on a <strong>Crocus</strong> <strong>SHDSL</strong> G703 2P (2 pair) version.<br />

Use the txEocMessages attribute to send EOC messages on both line pair 1 and 2 (bothPairs) or on line pair<br />

1 only (pair1).<br />

crocusShdslTtRpG703/line/eocHandling<br />

Default:none<br />

Range: enumerated, see below<br />

<strong>SHDSL</strong> devices can communicate with each other through the Embedded<br />

Operations Channel (EOC). Use the eocHandling attribute to define the handling of the EOC messages.<br />

For more information on EOC handling, refer to 5.2 - Configuring EOC handling on page 57.<br />

crocusShdslTtRpG703/line/numExpectedRepeaters<br />

Default:0<br />

Range: 0 … 8<br />

Use the numExpectedRepeaters attribute to set the number of <strong>Crocus</strong> <strong>SHDSL</strong><br />

G703 Repeaters that the <strong>Crocus</strong> <strong>SHDSL</strong> G703 can expect to find on the <strong>SHDSL</strong> line. If the actual<br />

number of repeaters does not match the number you entered in the numExpectedRepeaters attribute, then<br />

the invalidNumRepeaters alarm is raised.