136 <strong>Crocus</strong> <strong>SHDSL</strong> G703 Chapter 6<br />

Reference manual<br />

Configuration attributes<br />

Configuring the retrain criteria<br />

The retrain structure contains the following elements:<br />

Element<br />

enabled<br />

Use this element to enable (yes) or disable (no) retraining.<br />

So when selecting no, the <strong>Crocus</strong> <strong>SHDSL</strong> G703<br />

will never retrain (even not when the line is disconnected).<br />

errorPersistence-<br />

Time<br />

Description<br />

Use this element to set the period, in seconds, during<br />

which each criterion is measured. If within this period<br />

the predefined criterion value is equalled or<br />

exceeded, the <strong>Crocus</strong> <strong>SHDSL</strong> G703 retrains.<br />

Default:yes<br />

Range: -<br />

Default:10<br />

Range: -1 … 30<br />

The errorPersistenceTime functions as a moving window, so it ‘s always the last seconds,<br />

equal to the errorPersistenceTime, that are used to calculate the average.<br />

errorThreshold<br />

Use this element to set the amount of CRC errors, per<br />

mille, at which the <strong>Crocus</strong> <strong>SHDSL</strong> G703 should<br />

retrain. If the amount of CRC errors exceeds this<br />

Default:10<br />

Range: 1 … 300<br />

value (measured during the errorPersistenceTime), then the <strong>Crocus</strong> <strong>SHDSL</strong> G703<br />

retrains.<br />

Remark<br />

The errored <strong>SHDSL</strong> frames can be monitored using the performance attribute<br />

crocusShdslTtRpG703/line/linePair[ ]/performance/codeViolations.<br />

snrThreshold<br />

Use this element to set the signal to noise ratio, in dB, Default:23<br />

which has to be maintained. If the measured signal to Range: 20 … 25<br />

noise ratio drops below this value (measured during<br />

the errorPersistenceTime), then the <strong>Crocus</strong> <strong>SHDSL</strong> G703 retrains.<br />

If you configured the <strong>Crocus</strong> <strong>SHDSL</strong> G703 in …<br />

• a fixed speed, then the <strong>Crocus</strong> <strong>SHDSL</strong> G703 tries to retrain again at this fixed<br />

speed. If the retrain is successful, then the <strong>Crocus</strong> <strong>SHDSL</strong> G703 operates at<br />

this fixed speed again. If the retrain is not successful, then the <strong>Crocus</strong> <strong>SHDSL</strong><br />

G703 retrains again. If the line conditions are so bad that the fixed speed can<br />

no longer be attained, then the <strong>Crocus</strong> <strong>SHDSL</strong> G703 keeps retraining.<br />

• auto speed, then the <strong>Crocus</strong> <strong>SHDSL</strong> G703 initially tries to retrain at the speed<br />

it was trained before. If this does not work, then it tries to train on a lower speed.<br />

Remark<br />

The snrThreshold is only taken into account as a retrain criterion after the line has<br />

been in data state for 2 minutes.