126 Crocus SHDSL G703 Chapter 6 Reference manual Configuration attributes 6.2 General configuration attributes This section describes the following configuration attributes: • crocusShdslTtRpG703/sysName on page 127 • crocusShdslTtRpG703/sysContact on page 127 • crocusShdslTtRpG703/sysLocation on page 127 • crocusShdslTtRpG703/security on page 127 • crocusShdslTtRpG703/forwardTmaToCtrlPort on page 128 • crocusShdslTtRpG703/forwardTmaToLine on page 128 • crocusShdslTtRpG703/ on page 128 This section describes the following actions: • crocusShdslTtRpG703/Activate Configuration on page 129 • crocusShdslTtRpG703/Load Default Configuration on page 129 • crocusShdslTtRpG703/Load Saved Configuration on page 130 • crocusShdslTtRpG703/Cold Boot on page 130

Crocus SHDSL G703 Chapter 6 127 Reference manual Configuration attributes crocusShdslTtRpG703/sysName This is a field where you can assign a name to the Crocus SHDSL G703. The field has a limit of 64 characters. This is a SNMP MIB2 parameter. Default: Range: 0 … 64 characters crocusShdslTtRpG703/sysContact Default: Range: 0 … 64 characters This is a field where you can fill in the name of a contact person together with information on how to contact this person. The field has a limit of 64 characters. This is a SNMP MIB2 parameter. crocusShdslTtRpG703/sysLocation This is a field where you can fill in the physical location of the Crocus SHDSL G703. The field has a limit of 64 characters. This is a SNMP MIB2 parameter. Default: Range: 0 … 64 characters crocusShdslTtRpG703/security Default: Range: table, see below In order to avoid unauthorised access to the network and the Crocus SHDSL G703, you can create a list of passwords with associated access levels. The security attribute contains the following elements: Element password Description The password is a string of maximum 10 characters. Default: Range: 0 … 10 characters accessRights This attribute represents the access levels assigned to a password. It is a bit string whereof each bit corresponds to an access level. The different access levels are:· • readAccess • writeAccess· • securityAccess • fileSystemAccess • testAccess Default:11111 Range: bit string, see below

<strong>Crocus</strong> <strong>SHDSL</strong> G703 Chapter 6 127<br />

Reference manual<br />

Configuration attributes<br />

crocusShdslTtRpG703/sysName<br />

This is a field where you can assign a name to the <strong>Crocus</strong> <strong>SHDSL</strong> G703.<br />

The field has a limit of 64 characters.<br />

This is a SNMP MIB2 parameter.<br />

Default:<br />

Range: 0 … 64 characters<br />

crocusShdslTtRpG703/sysContact<br />

Default:<br />

Range: 0 … 64 characters<br />

This is a field where you can fill in the name of a contact person together<br />

with information on how to contact this person. The field has a limit of 64 characters.<br />

This is a SNMP MIB2 parameter.<br />

crocusShdslTtRpG703/sysLocation<br />

This is a field where you can fill in the physical location of the <strong>Crocus</strong><br />

<strong>SHDSL</strong> G703. The field has a limit of 64 characters.<br />

This is a SNMP MIB2 parameter.<br />

Default:<br />

Range: 0 … 64 characters<br />

crocusShdslTtRpG703/security<br />

Default:<br />

Range: table, see below<br />

In order to avoid unauthorised access to the network and the <strong>Crocus</strong><br />

<strong>SHDSL</strong> G703, you can create a list of passwords with associated access levels. The security attribute<br />

contains the following elements:<br />

Element<br />

password<br />

Description<br />

The password is a string of maximum 10 characters.<br />

Default:<br />

Range: 0 … 10 characters<br />

accessRights<br />

This attribute represents the access levels assigned<br />

to a password. It is a bit string whereof each bit corresponds<br />

to an access level. The different access levels<br />

are:·<br />

• readAccess<br />

• writeAccess·<br />

• securityAccess<br />

• fileSystemAccess<br />

• testAccess<br />

Default:11111<br />

Range: bit string, see below