98 Crocus SHDSL G703 Chapter 5 User manual Step-by-step configuration 5.9 Configuring the interface specific attributes crocusShdslTtRpG703/g703/coding Use the coding attribute to set the G703 interface encoding mode. Possible values are: Default:hdb3 Range: ami / hdb3 Value ami hdb3 Description Alternate Mark Inversion is selected. This is a bipolar code with no zero substitution. High Density Bipolar 3 is selected. This is a modified bipolar code.With HDB3 encoding, more than three consecutive zeroes occurring in the data are replaced by a substitution word. This to ensure a high pulse density. Therefore, data links using the HDB3 code can carry data patterns with a low 1 density. Most of the G703 applications use HDB3 encoding. crocusShdslTtRpG703/g703/crc4Insertion This attribute is only relevant in framed mode. Use the crc4Insertion attribute to determine whether the CRC-4 (cyclic redundancy check) is recalculated before sending it to the interface. The CRC is used to check the data integrity on the G.703 connection. The crc4Insertion attribute has the following possible values: Default:auto Range: enumerated, see below Value auto disabled enabled Description In auto mode, CRC-4 insertion is …· • disabled if the data is unframed,· • enabled if the data is G.704 framed. CRC-4 insertion is disabled. CRC-4 insertion is enabled.

Crocus SHDSL G703 Chapter 5 99 User manual Step-by-step configuration 5.10 Configuring the management attributes This section explains the management attributes of the Crocus SHDSL G703. These attributes allow you to make all the devices in your network accessible for management from one central location. First this section gives you some rules of thumb and remarks concerning the management of the Crocus SHDSL G703 in a network. Then it explains the attributes that have an impact on the management of the Crocus SHDSL G703. Finally, it gives some examples of networks and how to configure the Crocus SHDSL G703 to make it accessible for the central management system. The following gives an overview of this section: • 5.10.1 - Rules of thumb and remarks concerning management on page 100 • 5.10.2 - Using relative or absolute addressing on page 101 • 5.10.3 - Selecting the purpose of the control connector on page 102 • 5.10.4 - Forwarding management data to the line and control connector on page 103 • 5.10.5 - Configuring the management data on the line on page 105 • 5.10.6 - Configuring the management data on a G703 interface on page 106 • 5.10.7 - Example - management over the line and the control port on page 107 • 5.10.8 - Example - management over the line and the E1 interface on page 109

<strong>Crocus</strong> <strong>SHDSL</strong> G703 Chapter 5 99<br />

User manual<br />

Step-by-step configuration<br />

5.10 Configuring the management attributes<br />

This section explains the management attributes of the <strong>Crocus</strong> <strong>SHDSL</strong> G703. These attributes allow you<br />

to make all the devices in your network accessible for management from one central location.<br />

First this section gives you some rules of thumb and remarks concerning the management of the <strong>Crocus</strong><br />

<strong>SHDSL</strong> G703 in a network. Then it explains the attributes that have an impact on the management of<br />

the <strong>Crocus</strong> <strong>SHDSL</strong> G703. Finally, it gives some examples of networks and how to configure the <strong>Crocus</strong><br />

<strong>SHDSL</strong> G703 to make it accessible for the central management system.<br />

The following gives an overview of this section:<br />

• 5.10.1 - Rules of thumb and remarks concerning management on page 100<br />

• 5.10.2 - Using relative or absolute addressing on page 101<br />

• 5.10.3 - Selecting the purpose of the control connector on page 102<br />

• 5.10.4 - Forwarding management data to the line and control connector on page 103<br />

• 5.10.5 - Configuring the management data on the line on page 105<br />

• 5.10.6 - Configuring the management data on a G703 interface on page 106<br />

• 5.10.7 - Example - management over the line and the control port on page 107<br />

• 5.10.8 - Example - management over the line and the E1 interface on page 109