Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Tab. 3<br />
1<br />
UNIT<br />
3 4 12 13 14 15 16 17 18 19 20 21 22 23 24<br />
Model Form Voltage Absorbtion Line cable Cold room Fans/heaters Heaters Fans Auxiliary Door microswitch Remote control Door heater Room and defrost Capacity control<br />
supply power light cable cable cable cable cable cable panel cable cable probe cable probe cable<br />
V/Ph/Hz kW MAX no. of Ø no. of Ø no. of Ø no. of Ø no. of Ø no. of Ø no. of Ø no. of Ø no. of Ø no. of Ø no. of Ø<br />
wires (mm 2 ) wires (mm 2 ) wires (mm 2 ) wires (mm 2 ) wires (mm 2 ) wires (mm 2 ) wires (mm 2 ) wires (mm 2 ) wires (mm 2 ) wires (mm 2 ) wires (mm 2 )<br />
UTN122 2A 230/1/50 1,42 - - - - - - - - - - - - - - - - - - - - - -<br />
UTN120 2A 400/3/50 1,46 - - - - - - - - - - - - - - - - - - - - - -<br />
UTN132 2B 230/1/50 1,96 - - - - - - - - - - - - - - - - - - - - - -<br />
UTN130 2B 400/3/50 1,94 - - - - - - - - - - - - - - - - - - - - - -<br />
UTN180 3A 400/3/50 2,17 - - - - - - - - - - - - - - - - - - - - - -<br />
UTN250 3B 400/3/50 2,87 - - - - - - - - - - - - - - - - - - - - - -<br />
UTN330 4A 400/3/50 3,64 - - - - - - - - - - - - - - - - - - - - - -<br />
UTN430 4A 400/3/50 4,14 - - - - - - - - - - - - - - - - - - - - - -<br />
UTN490 4B 400/3/50 4,82 - - - - - - - - - - - - - - - - - - - - - -<br />
UTK170 2A 230/1/50 1,30 - - - - - - - - - - - - - - - - - - - - - -<br />
UTK220 2A 400/3/50 1,86 - - - - - - - - - - - - - - - - - - - - - -<br />
UTK300 2B 400/3/50 2,31 - - - - - - - - - - - - - - - - - - - - - -<br />
UTK450 3A 400/3/50 3,42 - - - - - - - - - - - - - - - - - - - - - -<br />
UTK490 3B 400/3/50 4,12 - - - - - - - - - - - - - - - - - - - - - -<br />
UTK620 4B 400/3/50 5,87 - - - - - - - - - - - - - - - - - - - - - -<br />
QTN060 2A 230/1/50 0,87 3 2,5 - - - - - - - - - - - - - - - - - - - -<br />
QTN075 2A 230/1/50 1,09 3 2,5 - - - - - - - - - - - - - - - - - - - -<br />
QTN100 2A 230/1/50 1,32 3 4 - - - - - - - - - - - - - - - - - - - -<br />
QTN122 2A 230/1/50 1,42 3 4 - - - - - - - - - - - - - - - - - - - -<br />
QTN120 2A 400/3/50 1,46 5 1,5 - - - - - - - - - - - - - - - - - - - -<br />
QTN132 2B 230/1/50 1,96 3 4 - - - - - - - - - - - - - - - - - - - -<br />
QTN130 2B 400/3/50 1,94 5 1,5 - - - - - - - - - - - - - - - - - - - -<br />
QTN180 3A 400/3/50 2,17 5 2,5 - - - - - - - - - - - - - - - - - - - -<br />
QTN250 3B 400/3/50 2,87 5 2,5 - - - - - - - - - - - - - - - - - - - -<br />
QTN330 4A 400/3/50 3,64 5 2,5 - - - - - - - - - - - - - - - - - - - -<br />
QTN430 4A 400/3/50 4,14 5 4 - - - - - - - - - - - - - - - - - - - -<br />
QTN490 4B 400/3/50 4,82 5 4 - - - - - - - - - - - - - - - - - - - -<br />
QTK170 2A 230/1/50 1,30 3 4 - - - - - - - - - - - - - - - - - - - -<br />
QTK220 2A 400/3/50 1,86 5 1,5 - - - - - - - - - - - - - - - - - - - -<br />
QTK300 2B 400/3/50 2,31 5 1,5 - - - - - - - - - - - - - - - - - - - -<br />
QTK450 3A 400/3/50 3,42 5 4 - - - - - - - - - - - - - - - - - - - -<br />
QTK490 3B 400/3/50 4,12 5 4 - - - - - - - - - - - - - - - - - - - -<br />
QTK620 4B 400/3/50 5,87 5 4 - - - - - - - - - - - - - - - - - - - -<br />
HTN060 2A 230/1/50 0,95 3 2,5 - - 4 1,5 - - - - - - - - 2 0,5* - - 4 0,75* - -<br />
HTN075 2A 230/1/50 1,26 3 4 - - 4 1,5 - - - - - - - - 2 0,5* - - 4 0,75* - -<br />
HTN100 2A 230/1/50 1,46 3 4 - - 4 1,5 - - - - - - - - 2 0,5* - - 4 0,75* - -<br />
HTN122 2A 230/1/50 1,57 3 4 - - 4 1,5 - - - - - - - - 2 0,5* - - 4 0,75* - -<br />
HTN120 2A 400/3/50 1,61 5 2,5 - - 4 1,5 - - - - - - - - 2 0,5* - - 4 0,75* - -<br />
HTN132 2B 230/1/50 2,23 3 6 - - 4 1,5 - - - - - - - - 2 0,5* - - 4 0,75* - -<br />
HTN130 2B 400/3/50 2,23 5 4 - - 4 1,5 - - - - - - - - 2 0,5* - - 4 0,75* - -<br />
HTN180 3A 400/3/50 2,39 5 4 - - 4 1,5 - - - - - - - - 2 0,5* - - 4 0,75* - -<br />
HTN250 3B 400/3/50 3,09 5 4 - - 7 1,5 - - - - - - - - 2 0,5* - - 4 0,75* - -<br />
HTN330 4A 400/3/50 3,92 5 6 - - - - 5 2,5 3 1,5 - - - - 2 0,5* - - 4 0,75* - -<br />
HTN430 4A 400/3/50 5,22 5 4 - - - - 5 4 3 1,5 - - - - 2 0,5* - - 4 0,75* - -<br />
HTN490 4B 400/3/50 6,13 5 10 - - - - 5 4 3 1,5 - - - - 2 0,5* - - 4 0,75* - -<br />
HTK170 2A 230/1/50 1,45 3 4 - - 4 1,5 - - - - - - - - 2 0,5* 3 1 4 0,75* - -<br />
HTK220 2A 400/3/50 1,88 5 4 - - 4 1,5 - - - - - - - - 2 0,5* 3 1 4 0,75* - -<br />
HTK300 2B 400/3/50 2,45 5 4 - - 7 1,5 - - - - - - - - 2 0,5* 3 1 4 0,75* - -<br />
HTK450 3A 400/3/50 4,02 5 6 - - - - 5 2,5 3 1,5 - - - - 2 0,5* 3 1 4 0,75* - -<br />
HTK490 3B 400/3/50 5,20 5 6 - - - - 5 2,5 3 1,5 - - - - 2 0,5* 3 1 4 0,75* - -<br />
HTK620 4B 400/3/50 6,13 5 10 - - - - 5 4 3 1,5 - - - - 2 0,5* 3 1 4 0,75* - -<br />
HDA130 3A 400/3/50 2,40 5 2,5 - - - - - - 3 1,5 - - - - 2 0,5* - - 2 0,5* - -<br />
HDA180 3B 400/3/50 2,71 5 2,5 - - - - - - 3 1,5 - - - - 2 0,5* - - 2 0,5* - -<br />
HDA250 4A 400/3/50 3,51 5 2,5 - - - - - - 3 1,5 - - - - 2 0,5* - - 2 0,5* - -<br />
HDA330 4B 400/3/50 4,53 5 4 - - - - - - 3 1,5 - - - - 2 0,5* - - 2 0,5* - -<br />
HDA430 4D 400/3/50 5,50 5 4 - - - - - - 3 1,5 - - - - 2 0,5* - - 2 0,5* - -<br />
HDA490 4D 400/3/50 6,68 5 6 - - - - - - 3 1,5 - - - - 2 0,5* - - 2 0,5* - -<br />
HDA550 4G 400/3/50 6,88 5 6 - - - - - - 3 1,5 - - - - 2 0,5* - - 2 0,5* - -<br />
RTY101 - 230/1/50 1,66 3 4 - - - - - - - - - - - - - - - - - - - -<br />
RTY121 - 400/3/50 1,77 5 1,5 - - - - - - - - - - - - - - - - - - - -<br />
RTY151 - 400/3/50 2,37 5 2,5 - - - - - - - - - - - - - - - - - - - -<br />
RTY201 - 400/3/50 2,66 5 2,5 - - - - - - - - - - - - - - - - - - - -<br />
RTZ101 - 230/1/50 1,66 3 4 - - - - - - - - - - - - - - - - - - - -<br />
RTZ121 - 400/3/50 1,77 5 1,5 - - - - - - - - - - - - - - - - - - - -<br />
RTZ151 - 400/3/50 2,37 5 2,5 - - - - - - - - - - - - - - - - - - - -<br />
RTZ201 - 400/3/50 2,66 5 2,5 - - - - - - - - - - - - - - - - - - - -<br />
*= shield<br />
11