Hangers - USP Connectors

Hangers - USP Connectors Hangers - USP Connectors

uspconnectors.com
from uspconnectors.com More from this publisher
29.12.2014 Views

Rod Chairs – RCD & RCT Rod chairs hold reinforcing bars for proper placement during the pouring or application of concrete. Materials: Welded Wire Finish: None RCD Typical RCD installation Concrete & Masonry USP Stock No. Ref. No. Description Dimensions (in) RCD -- -- Double Rod Chair 4 x 5 x 8-1/4 RCT -- -- Triple Rod Chair 3-1/2 x 4 x 12 Safety Caps – SCV & SCH series Bright orange safety caps protect against injuries from vertical rebar. RCT Typical RCT installation © Copyright 2013 USP Structural Connectors ® Materials: Composite Plastic Finish: None SCV Typical SCV installation USP Stock No. Ref. No. Description Dimensions (in) SCH -- -- Horizontal Safety Cap 2-3/8 x 2-1/2 x 2-1/2 SCV -- -- Vertical Safety Cap 3-1/4 x 3-3/4 x 3-3/4 Anchor Bolt Stabber (Bolt Rite) – ABS12 SCH Typical SCH installation For accurate placement of 1/2˝ (12.7 mm) anchor bolts in wet concrete. The outstanding legs are different lengths, with the shorter leg centering the anchor bolt in a 2 x 4 sill plate and the longer leg centering the anchor bolt in a 2 x 6 sill plate. Materials: Composite Plastic Finish: See chart Patents: Pending Installation: • Slide ABS over anchor bolt and screw on cap. • Place bolt in wet concrete using guides for proper edge distance. USP Bolt Dia. Stock No. 1 Ref. No. (in) Color ABS12 -- -- 1/2 orange 1) Anchor bolt caps are included with product. ABS12 Typical ABS12 installation 28 1-800-328-5934 • www.USPconnectors.com

Threaded Rods – THR series USP has added longer length THR’s to support the new deck oriented code requirements for mechanically reinforced railing post and deck to house ledger board attachments. Materials: ASTM A 36 Steel, also conforms to ASTM F 1554 Grade 36 Finish: Hot-dip galvanized L © Copyright 2013 USP Structural Connectors ® Installation: • Install into wet concrete or drill minimum 1 ⁄16" oversized hole and secure with anchor epoxy. • Nuts and washers are included. USP Stock No. Ref. No. Bolt Dia. (in) L (in) THR125-HDG RFB#4X5HDG 1/2 5 THR126-HDG RFB#4X6HDG 1/2 6 THR128-HDG RFB#4X8HDG 1/2 8 THR1218-HDG -- -- 1/2 18 THR1224-HDG -- -- 1/2 24 THR1236-HDG -- -- 1/2 36 THR585-HDG RFB#5X5HDG 5/8 5 THR588-HDG RFB#5X8HDG 5/8 8 THR5812-HDG RFB#5X12HDG 5/8 12 THR5816-HDG RFB#5X16HDG 5/8 16 New products or updated product information are designated in red font. NEW SIZES Epoxy Coated Rebar – CRE24 THR ½" THR Threaded Rod Typical THR installation DTB-TZ Page 195 Typical THR Deck to ledger installation Concrete & Masonry Two-foot epoxy coated rebar provides maximum protection against corrosion. Materials: A615 Steel Finish: Epoxy Dipped USP Dimensions Stock No. Ref. No. Dia L CRE24 -- -- 10 mm 24" Round Nail Stake – NSR Nail stakes are used to secure form boards to prevent movement and bowing. Materials: Steel Finish: Black Primer Installation: • Fastener holes will accommodate up to a 16d duplex nail. USP Dimensions (in) Stock No. Ref. No. Dia L NSR -- -- 3/4 18 Retro Plate – RP6 Uses heavy gauge HRPO steel and a large surface area to distribute seismic forces on masonry exteriors. L CRE24 NSR Typical CRE24 installation Typical NSR installation Materials: 3/8˝ plate Finish: USP primer Options: RP6 is available in Hot-dip galvanized. To order add HDG to stock number, as in RP6-HDG. 6˝ 3˝ 3/4˝ dia. threaded rod Installation: • Install with a 3/4˝ diameter steel threaded rod. USP Stock No. Ref. No. RP6 RP6 3˝ 6˝ RP6 Typical RP6 installation 1-800-328-5934 • www.USPconnectors.com 29 USP2240-131

Rod Chairs – RCD & RCT<br />

Rod chairs hold reinforcing bars for proper placement<br />

during the pouring or application of concrete.<br />

Materials: Welded Wire<br />

Finish: None<br />

RCD<br />

Typical RCD<br />

installation<br />

Concrete & Masonry<br />

<strong>USP</strong><br />

Stock No.<br />

Ref. No.<br />

Description<br />

Dimensions<br />

(in)<br />

RCD -- -- Double Rod Chair 4 x 5 x 8-1/4<br />

RCT -- -- Triple Rod Chair 3-1/2 x 4 x 12<br />

Safety Caps – SCV & SCH series<br />

Bright orange safety caps protect against injuries from vertical rebar.<br />

RCT<br />

Typical RCT<br />

installation<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Materials: Composite Plastic<br />

Finish: None<br />

SCV<br />

Typical SCV<br />

installation<br />

<strong>USP</strong><br />

Stock No. Ref. No. Description Dimensions (in)<br />

SCH -- -- Horizontal Safety Cap 2-3/8 x 2-1/2 x 2-1/2<br />

SCV -- -- Vertical Safety Cap 3-1/4 x 3-3/4 x 3-3/4<br />

Anchor Bolt Stabber (Bolt Rite) – ABS12<br />

SCH<br />

Typical SCH<br />

installation<br />

For accurate placement of 1/2˝ (12.7 mm) anchor bolts in wet concrete. The<br />

outstanding legs are different lengths, with the shorter leg centering the anchor<br />

bolt in a 2 x 4 sill plate and the longer leg centering the anchor bolt in a 2 x 6<br />

sill plate.<br />

Materials: Composite Plastic<br />

Finish: See chart<br />

Patents: Pending<br />

Installation:<br />

• Slide ABS over anchor bolt and screw on cap.<br />

• Place bolt in wet concrete using guides for proper edge distance.<br />

<strong>USP</strong><br />

Bolt Dia.<br />

Stock No. 1<br />

Ref. No. (in) Color<br />

ABS12 -- -- 1/2 orange<br />

1) Anchor bolt caps are included with product.<br />

ABS12<br />

Typical ABS12<br />

installation<br />

28<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!